Clean strainer in water

connection

Fig. 11

!

 Remove strainer

!

  Clean in water and re-insert

Clean the fine filter

Fig. 12

!

  Cut pressure to unit

!

  Screw off cover with filter

!

  Clean filter with clean water or with

compressed air

!

  Assemble in the reverse order

Clean strainer in low water

protection

Fig. 13

!

  Unfasten union nut and detach hose

Fig. 14

!

 Take out strainer

If necessary, screw-in screw M8 by
approx. 5 mm and pull out the strainer with
this screw

!

  Clean strainer in water

!

  Slide in strainer

!

 Mount hose

!

  Tighten union nut

Clean filter at cleaning-agent

suction hose

Fig. 15

!

  Pull the cleaning agent suction inlet pipe

out

!

  Clean filter in water and re-insert

Change oil

Fig. 16

!

  Provide a collecting container for

approx. 1 litres of oil

!

  Unscrew drain plug

Dispose of used oil ecologically or hand it
in at a dump.

!

 Retighten drain plug

!

  Top up oil slowly up to the MAX mark

Air bubbles must be able to escape
Refer to technical data for oil grade and
quantity to be used.

Faults

Engine/electronics indicator lamp
(item 28) flashes

 This warning lamp flashes if there is a

problem.

!

  When you open the cover (item 8) of the

compartment (item 6) the electronic
display is visible in the window (item 4).

!

  The warning lamp goes out when the

problem has been resolved and the unit
is switched on again.

Display

Troubleshooting

!

  Increase the water inlet volume

!

  Clean strainer in water connection

!

  Clean the strainer (coarse) fitted in front

of the low water protection

Summary of Contents for HDS 995 MX Eco

Page 1: ...www kaercher com 5 961 300 A2008544 05 04 HDS 995 M Eco HDS 995 MX Eco HDS 1295 S Eco HDS 1295 SX Eco...

Page 2: ...is Italiano Nederlands Espa ol Portugu s Dansk Norsk Svenska Suomi Magyar esky Slovensko Polska Rom ne te T rk e Slovensky Hrvatski Srpski 38 7 23 55 72 88 138 104 120 153 168 183 230 198 214 246 263...

Page 3: ......

Page 4: ...1 2 3 4 5 6a 6b 7...

Page 5: ...8 9 10 11a 11b 12 13 14...

Page 6: ...15 16 17 18 19...

Page 7: ...Inform retailer immediately of any transportation damage Environmental protection Please dispose of packaging environmentally responsibly The packaging materials are recyclable Please do not throw the...

Page 8: ...4 Handle grips in the chassis 15 Steel pipe 16 Pressure and flow control 17 Swivel caster with parking brake 18 Water connection with strainer 19 High pressure connection 20 Handgun with high pressure...

Page 9: ...rd tap water Is is metered in at the inlet in the water reservoir one drop at a time By the manufacturer metering is set to a mean water hardness For other water hardnesses request services of a K rch...

Page 10: ...ata for connected loads Install supply hose at water connection item 18 of unit supply hose is not part of scope of delivery Drawing in water from tank When you suction water out of an open container...

Page 11: ...er to Faults Fig 9 Release the safety of the handgun A Actuation of handgun switches unit back on again Bleed pump if no water emerges from high pressure nozzle See problems Unit does not build up pre...

Page 12: ...h pressure nozzle Spray angle is crucial to efficiency of high pressure jet Use is normally made of 25 fan jet nozzle included Recommended nozzles available as accessories For stubborn dirt 0 full jet...

Page 13: ...ly open water delivery control at the handgun in the direction to the stop See Figure 9 B Set operating pressure to minimum value See Fig 10 Set the temperature regulator item 24 to min 100 C Danger S...

Page 14: ...nd high pressure hose Screw off supply line at boiler base and completely drain heating coil Run unit for max 1 min until pump and lines are empty Flushing unit with anti freeze Fill the float tank wi...

Page 15: ...tenance work has been completed you should depress the RESET button next to the display for at least 7 seconds until the warning lamp goes out Display Necessary maintenance work Visual inspection Chec...

Page 16: ...inlet pipe out Clean filter in water and re insert Change oil Fig 16 Provide a collecting container for approx 1 litres of oil Unscrew drain plug Dispose of used oil ecologically or hand it in at a du...

Page 17: ...rvice Ready for working indicator lamp item 29 goes out Motor overloaded overheated Set selector switch to 0 and allow engine to cool off for at least 5 min Have unit checked by After Sales Service if...

Page 18: ...agent the reasons can be as follows Filter in cleaning agent suction hose dirty Clean filter Non return valve gummed up Pull the cleaning agent hose off and detach the non return valve with a blunt o...

Page 19: ...de If the handgun is closed off so that all the water flows back to the pump suction side the pressure switch at the overflow valve turns off the pump Reopening the handgun causes the pressure switch...

Page 20: ...DIN EN 55014 1 2000 A1 2001 DIN EN 55014 2 1997 DIN EN 61000 3 2 2000 DIN EN 61000 3 3 1995 A1 2001 HDS 995 DIN EN 61000 3 11 2000 HDS 1295 Applied national standards Applied conformity valuation met...

Page 21: ...pressure steam max 3 2 MPa 32 bar max 2 8 MPa 28 bar Steam nozzle part number 4 766 023 4 766 024 Operating temperature Hot water max 95 C max 95 C Steam 98 155 C 98 155 C Cleaning agent intake 0 40 l...

Page 22: ...379...

Page 23: ...380...

Reviews: