English Operating
Instructions
32
Clean strainer in water
connection
Fig. 11
!
Remove strainer
!
Clean in water and re-insert
Clean the fine filter
Fig. 12
!
Cut pressure to unit
!
Screw off cover with filter
!
Clean filter with clean water or with
compressed air
!
Assemble in the reverse order
Clean strainer in low water
protection
Fig. 13
!
Unfasten union nut and detach hose
Fig. 14
!
Take out strainer
If necessary, screw-in screw M8 by
approx. 5 mm and pull out the strainer with
this screw
!
Clean strainer in water
!
Slide in strainer
!
Mount hose
!
Tighten union nut
Clean filter at cleaning-agent
suction hose
Fig. 15
!
Pull the cleaning agent suction inlet pipe
out
!
Clean filter in water and re-insert
Change oil
Fig. 16
!
Provide a collecting container for
approx. 1 litres of oil
!
Unscrew drain plug
Dispose of used oil ecologically or hand it
in at a dump.
!
Retighten drain plug
!
Top up oil slowly up to the MAX mark
Air bubbles must be able to escape
Refer to technical data for oil grade and
quantity to be used.
Faults
Engine/electronics indicator lamp
(item 28) flashes
—
This warning lamp flashes if there is a
problem.
!
When you open the cover (item 8) of the
compartment (item 6) the electronic
display is visible in the window (item 4).
!
The warning lamp goes out when the
problem has been resolved and the unit
is switched on again.
Display
Troubleshooting
!
Increase the water inlet volume
!
Clean strainer in water connection
!
Clean the strainer (coarse) fitted in front
of the low water protection