Operating Instructions
English
33
Display
Troubleshooting
!
Replace the reed switch for the low
water protection *
!
Clean the low water protection *
Display
Troubleshooting
!
Eliminate the leakage in the high-
pressure system
Display
Troubleshooting
Motor overloaded/overheated
!
Turn monitoring switch to "0" and allow
engine to cool for at least 5 min
!
Have unit checked by After-Sales
Service if this does not remedy fault
!
Cbeck exhaust gas temperature limiter,
reset, if necessary (Figure 19)
Display
Troubleshooting
!
This error code appears only on units
equipped with the – accessory kit flame
monitoring system -
!
See the assembly instructions –
accessory kit flame monitoring system -
* This maintenance work should be
performed only by after-sales service.
Ready for working indicator lamp
(item 29) goes out
—
Motor overloaded/overheated
!
Set selector switch to "0" and allow
engine to cool off for at least 5 min.
!
Have unit checked by After-Sales
Service if this does not remedy fault.
!
No mains voltage
(see – unit does not run -)
Fuel indicator lamp (item 25) lights up
—
Fuel tank empty
!
Fill up
Liquid softener indicator lamp (item 26)
lights up
—
Scale inhibitor reservoir empty; for
technical reasons there is always a
residual quantity in the reservoir.
!
Fill up
—
Dirt on electrodes in reservoir
!
Clean electrodes
Unit does not run
—
No mains voltage
!
Check electric mains/power cord
Unit does not build up pressure
—
Air in system
Bleed pump:
!
Set cleaning agent metering valve
(item 31) to "0"
!
Switch the unit switch on and off several
times keeping the handgun open.
!
With handgun open, open and close
regulator (Fig. 10).
Venting is accelerated by removing the
high-pressure hose from the high-pressure
connection.