Maintenance intervals

Once a week

 Clean strainer in water connection

 Clean the fine filter

 Check oil level

Immediately consult the Kärcher service
station when oil turns milky!

Once a month

 Clean strainer in low water protection

 Clean filter at cleaning-agent suction

hose

After 500 hours of operation, at least
once a year

 Change oil

Maintenance tasks

Engine/electronics indicator

lamp (item 28) is lit

 This warning lamp lights up when certain

maintenance work is necessary due to
accumulated operating hours.

!

  When you open the cover (item 8) of

the compartment (item 6) the electronic
display is visible in the window (item 4).

!

  When the necessary maintenance work

has been completed you should depress
the RESET button next to the display for
at least 7 seconds until the warning lamp
goes out.

Display

Necessary maintenance work

!

 Visual inspection

!

  Check that the high-pressure

connections do not leak

!

  Clean the fuel tank and the filter

Display

Necessary maintenance work

!

  Check that the pump does not leak

!

  Change the pump's oil

!

  Clean strainer in water connection

!

  Clean the strainer (coarse) fitted in front

of the low water protection

Display

Necessary maintenance work

!

  Decarbonise the heating coil *

!

  Descale the heating coil *

!

  Clean/replace the ignition electrodes *

!

  Cleaning/replacing the burner nozzle *

!

  Adjust the burner *

Display

Necessary maintenance work

!

  Check the overflow valve for leaks *

!

  Check the high-pressure hose *

!

  Clean the handgun

!

  Check the pulsation damper *

* This maintenance work should be
performed only by after-sales service.

Summary of Contents for HDS 995 MX Eco

Page 1: ...www kaercher com 5 961 300 A2008544 05 04 HDS 995 M Eco HDS 995 MX Eco HDS 1295 S Eco HDS 1295 SX Eco...

Page 2: ...is Italiano Nederlands Espa ol Portugu s Dansk Norsk Svenska Suomi Magyar esky Slovensko Polska Rom ne te T rk e Slovensky Hrvatski Srpski 38 7 23 55 72 88 138 104 120 153 168 183 230 198 214 246 263...

Page 3: ......

Page 4: ...1 2 3 4 5 6a 6b 7...

Page 5: ...8 9 10 11a 11b 12 13 14...

Page 6: ...15 16 17 18 19...

Page 7: ...Inform retailer immediately of any transportation damage Environmental protection Please dispose of packaging environmentally responsibly The packaging materials are recyclable Please do not throw the...

Page 8: ...4 Handle grips in the chassis 15 Steel pipe 16 Pressure and flow control 17 Swivel caster with parking brake 18 Water connection with strainer 19 High pressure connection 20 Handgun with high pressure...

Page 9: ...rd tap water Is is metered in at the inlet in the water reservoir one drop at a time By the manufacturer metering is set to a mean water hardness For other water hardnesses request services of a K rch...

Page 10: ...ata for connected loads Install supply hose at water connection item 18 of unit supply hose is not part of scope of delivery Drawing in water from tank When you suction water out of an open container...

Page 11: ...er to Faults Fig 9 Release the safety of the handgun A Actuation of handgun switches unit back on again Bleed pump if no water emerges from high pressure nozzle See problems Unit does not build up pre...

Page 12: ...h pressure nozzle Spray angle is crucial to efficiency of high pressure jet Use is normally made of 25 fan jet nozzle included Recommended nozzles available as accessories For stubborn dirt 0 full jet...

Page 13: ...ly open water delivery control at the handgun in the direction to the stop See Figure 9 B Set operating pressure to minimum value See Fig 10 Set the temperature regulator item 24 to min 100 C Danger S...

Page 14: ...nd high pressure hose Screw off supply line at boiler base and completely drain heating coil Run unit for max 1 min until pump and lines are empty Flushing unit with anti freeze Fill the float tank wi...

Page 15: ...tenance work has been completed you should depress the RESET button next to the display for at least 7 seconds until the warning lamp goes out Display Necessary maintenance work Visual inspection Chec...

Page 16: ...inlet pipe out Clean filter in water and re insert Change oil Fig 16 Provide a collecting container for approx 1 litres of oil Unscrew drain plug Dispose of used oil ecologically or hand it in at a du...

Page 17: ...rvice Ready for working indicator lamp item 29 goes out Motor overloaded overheated Set selector switch to 0 and allow engine to cool off for at least 5 min Have unit checked by After Sales Service if...

Page 18: ...agent the reasons can be as follows Filter in cleaning agent suction hose dirty Clean filter Non return valve gummed up Pull the cleaning agent hose off and detach the non return valve with a blunt o...

Page 19: ...de If the handgun is closed off so that all the water flows back to the pump suction side the pressure switch at the overflow valve turns off the pump Reopening the handgun causes the pressure switch...

Page 20: ...DIN EN 55014 1 2000 A1 2001 DIN EN 55014 2 1997 DIN EN 61000 3 2 2000 DIN EN 61000 3 3 1995 A1 2001 HDS 995 DIN EN 61000 3 11 2000 HDS 1295 Applied national standards Applied conformity valuation met...

Page 21: ...pressure steam max 3 2 MPa 32 bar max 2 8 MPa 28 bar Steam nozzle part number 4 766 023 4 766 024 Operating temperature Hot water max 95 C max 95 C Steam 98 155 C 98 155 C Cleaning agent intake 0 40 l...

Page 22: ...379...

Page 23: ...380...

Reviews: