English
HDS 798 C
9
Setting cleaning temperature
Set selector switch (1) to desired
temperature
30°C to 90°C
Hot water cleaning
100°C to 150°C
Steam cleaning (with steam nozzle
4.677023)
Setting operating pressure and
flow rate
Fig. 8
Turning regulator clockwise:
Increases operating pressure (MAX)
Turning counter-clockwise: Reduces
operating pressure (MIN)
Servopress control
Set selector switch (1) to max. 98°C.
Set regulator to maximum operating
pressure.
Fig. 11
Operating pressure and flow rate
can be set at handgun.
Set pressure on unit if use is to be
made of reduced pressure for a
lengthy period. See Fig. 8
Measuring out the cleaning agent
*
Use cleaning agents sparingly to
protect the environment
*
The cleaning agent must be
suitable for the surface to be
cleaned.
Fig. 10
Set cleaning-agent concentration as
specified by manufacturer
0 =Working without cleaning agent
Metering setting
Concentration
1
0,25%
2
1,00%
3
1,25%
4
1,50%
5
1,75%
6
2,00%
Approximate values at maximum
operating pressure
Intended use
Cleaning of: Machines, vehicles,
buildings, tools, facades, terraces,
garden tools, etc..
*
Engine cleaning is only to be
performed in areas provided with
oil separator.
*
Heed appropriate safety
regulations for use at petrol
stations or in other hazardous
environments.
Working with high-pressure
nozzle
Spray angle is crucial to efficiency of
high-pressure jet.
Use is normally made of 25°fan jet
nozzle (included).
Recommended nozzles, available as
accessories
–
For stubborn dirt 0°full jet nozzle
–
For delicate surfaces and slight
contamination 40°fan jet nozzle
–
For thick layers of stubborn dirt dirt
blaster
–
Nozzle with variable spray angle,
for adaptation to various cleaning
tasks variable-angle nozzle
Cleaning
*
Set pressure/temperature and
cleaning-agent concentration in
line with surface to be cleaned
*
To avoid damage from excessive
pressure, always direct the high-
pressure stream onto the object to
be cleaned from a sufficient
distance away.
Recommended cleaning method
Loosen up dirt:
Spray on cleaning agent sparingly
and allow to react for 1...5 min (do
not allow to dry on).
Remove dirt:
Spray off loosened-up dirt with high-
pressure jet.
Operation with cold water
Removal of slight contamination and
rinsing
e.g.: Garden implements, terrace,
tools, etc.
Set operating pressure as required
Set selector switch to "I"
Operation with hot water
*
Danger of scalding
We recommend the following
cleaning temperatures
–
Slight contamination 30-50°C
–
Protein soiling, e.g. in foodstuffs
industry max. 60°C