background image

English

HDS 798 C

7

OVERVIEW

Fig. 1
1 Swivel caster with parking brake
2 Connection for high-pressure hose
3 Fuel tank inlet
4 High-pressure hose
5 Cover latch
6 Handgun
7 Pressure gauge
8 Filler opening for cleaning agent
   and metering equipment
9 Water connection 1 with strainer

Fig. 2
1 Selector switch ON/OFF
   and temperature

Indicator lamps
2 Fuel empty
3 Liquid softener empty
4 Readiness for service

Fig. 3
Press down cover latch with
screwdriver or coin and turn counter-
clockwise to open.
To close, turn clockwise.

Fig. 4
Compartment for accessories
beneath cover
10 Steam nozzle
    (4.766023) optional

COMMISSIONING

  Unit, piping, high-pressure hose

and connections must be in
perfect working order!

  Lock the hand brake.

Checking oil level

Fig. 5

Prior to initial startup, cut off tip of oil
reservoir cap
Contact KÄRCHER AFTER-SALES
SERVICE immediately if oil is
opaque!
If oil level is approaching MIN mark,
fill up with oil as far as MAX mark.
Seal oil filler inlet.
Refer to technical data for oil grade.

Filling with scale inhibitor

Fig. 6
(sample pack included with scope of
delivery)

Scale inhibitor stops heating coil
becoming calcified when using hard
tap water. It is metered in at the
inlet in the water reservoir one drop
at a time.
The metering is set at the factory to
medium-hard water.

For other water hardness classes,
call in KÄRCHER AFTER-SALES
SERVICE to perform adjustment to
local conditions.

Filling with fuel

  Never operate unit with fuel tank

empty! Fuel pump would
otherwise be destroyed!

Fig. 7
Only fill with Kerosene
Close tank cap
Wipe off excess fuel

Filling with cleaning agent

*

  Only use KÄRCHER products.

*

  Never pour in solvent (petrol,

acetone, thinner etc.)!

*

  Avoid contact with eyes and skin

*

  Pay attention to cleaning-agent

manufacturer's instructions on
safety and handling

KÄRCHER can provide an
individual range of cleaning and
treatment agents.
Your dealer will be pleased to advise
you.

Fig. 9
Fill with cleaning agent

Summary of Contents for HDS 798 C

Page 1: ...HDS 798 C www karcher com 5 959 368 09 99 1 174...

Page 2: ...HDS 789 C 1 2 3 4 5 6 7 8 9 10 11 12...

Page 3: ...HDS 789 C 13 14 15 16 17 18 19 20...

Page 4: ...HDS 798 C Operating Instructions 5 Spare Parts List 14...

Page 5: ...tching on unit 8 Setting cleaning temperature 9 Setting operating pressure and flow rate 9 Measuring out the cleaning agent 9 Intended use 9 Cleaning 9 Operation with cold water 9 Operation with hot w...

Page 6: ...e all times Follow te maintenance instructions specified in the manual This product must connected to a power supply receptacle protected by a GFCI ground fault circuit interrupter If Replacement Of T...

Page 7: ...If oil level is approaching MIN mark fill up with oil as far as MAX mark Seal oil filler inlet Refer to technical data for oil grade Filling with scale inhibitor Fig 6 sample pack included with scope...

Page 8: ...wer plug Have power plug fitted by K RCHER AFTER SALES SERVICE or an authorised electrician Set selector switch to 0 Insert power plug Whenever socket is changed check direction of rotation of motor I...

Page 9: ...with oil separator Heed appropriate safety regulations for use at petrol stations or in other hazardous environments Working with high pressure nozzle Spray angle is crucial to efficiency of high pre...

Page 10: ...drained off completely Store unit in a frost free location Take unit out of service if frost free storage is not possible DISCONTINUATION OF USAGE In the event of lengthy periods of non use or if fros...

Page 11: ...off Motor overloaded overheated Set selector switch to 0 and allow motor to cool down for at least 5 min Have unit checked by After Sales Service if this does not remedy fault SCALE INHIBITOR indicat...

Page 12: ...ice and produce both accessories and proof of purchase GENERAL INSTRUCTIONS Safety features Overflow valve with two pressure switches When reducing water volume at pump head or with the servopress con...

Page 13: ...erating pressure cold hot water with standard nozzle supplied 32 150 bar Flow rate steam 360 l h Operating pressure steam with steam nozzle 4 766 023 max 32 bar Operating temperature Hot water max 90...

Page 14: ...HDS 798 C 14...

Reviews: