8

Mounting handgun

  Connect spray lance to handgun

  Insert high-pressure nozzle in

union nut

  Mount and tighten unit nut

  Mount high-pressure hose at high-

pressure connection Fig. 1 Item 2

Water connection

For connected loads, refer to
Technical Data.
Mount supply hose at water
connection of unit.
Illustration 1 Pos. 9,
(supply hose is not part of scope of
delivery)

Drawing in water from tank

The following conversion work is
necessary if water is to be drawn in
from an external tank.

Fig. 12
Lift off scale inhibitor reservoir.
Remove upper supply hose to water
reservoir and route to pump head.

Fig. 13
Detach water connection at pump
head and swivel aside.
Connect supply hose to pump head.

For drawing in, use 3/4 hose with
suction filter.
Max. suction height 0,5 m.

Mains connection

Refer to technical data and rating
plate for connected loads.

Fitting power plug
Have power plug fitted by
KÄRCHER AFTER-SALES
SERVICE or an authorised
electrician.

Set selector switch to "0"
Insert power plug

Whenever socket is changed,
check direction of rotation of
motor
If direction of rotation is correct,
powerful jet of air will be felt at
exhaust-gas opening of burner.
In the event of incorrect direction of
rotation, refer to Faults "Burner not
ignited"

If an extension cable is used, this
should always be fully uncoiled and
have an adequate cross-section.
(10 m min. 1,5 mm

2

, 30 m

min. 2.5 mm

2

)

OPERATION

*

  Never operate unit with fuel tank

empty! Fuel pump would
otherwise be destroyed!

Switching on unit

Fig. 2
Set selector switch (1) to "I"
Indicator lamp (4) lights

*

  If indicator lamp (2) or (3) comes

on during operation, switch off unit
immediately. Eliminate fault, refer
to Faults.

Unit starts up briefly and is switched
off as soon as operating pressure is
reached.
Fig. 11
Release handgun
Actuation of handgun switches unit
back on again.

Bleed pump if no water emerges
from high-pressure nozzle. Refer to
Faults "No build-up of pressure by
unit"

Summary of Contents for HDS 798 C

Page 1: ...HDS 798 C www karcher com 5 959 368 09 99 1 174...

Page 2: ...HDS 789 C 1 2 3 4 5 6 7 8 9 10 11 12...

Page 3: ...HDS 789 C 13 14 15 16 17 18 19 20...

Page 4: ...HDS 798 C Operating Instructions 5 Spare Parts List 14...

Page 5: ...tching on unit 8 Setting cleaning temperature 9 Setting operating pressure and flow rate 9 Measuring out the cleaning agent 9 Intended use 9 Cleaning 9 Operation with cold water 9 Operation with hot w...

Page 6: ...e all times Follow te maintenance instructions specified in the manual This product must connected to a power supply receptacle protected by a GFCI ground fault circuit interrupter If Replacement Of T...

Page 7: ...If oil level is approaching MIN mark fill up with oil as far as MAX mark Seal oil filler inlet Refer to technical data for oil grade Filling with scale inhibitor Fig 6 sample pack included with scope...

Page 8: ...wer plug Have power plug fitted by K RCHER AFTER SALES SERVICE or an authorised electrician Set selector switch to 0 Insert power plug Whenever socket is changed check direction of rotation of motor I...

Page 9: ...with oil separator Heed appropriate safety regulations for use at petrol stations or in other hazardous environments Working with high pressure nozzle Spray angle is crucial to efficiency of high pre...

Page 10: ...drained off completely Store unit in a frost free location Take unit out of service if frost free storage is not possible DISCONTINUATION OF USAGE In the event of lengthy periods of non use or if fros...

Page 11: ...off Motor overloaded overheated Set selector switch to 0 and allow motor to cool down for at least 5 min Have unit checked by After Sales Service if this does not remedy fault SCALE INHIBITOR indicat...

Page 12: ...ice and produce both accessories and proof of purchase GENERAL INSTRUCTIONS Safety features Overflow valve with two pressure switches When reducing water volume at pump head or with the servopress con...

Page 13: ...erating pressure cold hot water with standard nozzle supplied 32 150 bar Flow rate steam 360 l h Operating pressure steam with steam nozzle 4 766 023 max 32 bar Operating temperature Hot water max 90...

Page 14: ...HDS 798 C 14...