background image

English

HDS 798 C

12

Non-return valve gummed up

  Pull off cleaning-agent hose and

use blunt object to release non-
return valve (see Fig.20).

Burner not ignited
Fuel tank empty

 Fill up

Lack of water

  Check water connection, check

supply lines, clean low water
protection.

Fuel filter dirty

  Replace fuel filter.

Incorrect direction of rotation. If
direction of rotation is correct,
powerful jet of air will be felt at
exhaust-gas opening of burner.

  Check direction of rotation. If

necessary, have connection
replaced by a qualified electrician.

No ignition spark

  Have unit checked by After-Sales

Service if no ignition spark is
visible through inspection glass
during operation.

Set temperature not attained
when working with hot water
Excessive operating pressure/flow
rate

  Reduce operating pressure/flow

rate by way of regulator (Fig. 8)

Soot deposits on heating coil

  Have After-Sales Service remove

soot deposits from unit

If fault cannot be rectified, have
unit checked by After-Sales
Service.

WARRANTY

The warranty terms and conditions
issued by our responsible sales
company apply in every country.
Within the warranty period, any
faults in the unit will be rectified free
of charge provided that the problem
was caused by a material defect or
manufacturing error.

The warranty only applies if the
dealer fills in, stamps and signs the
enclosed reply card when the unit is
sold and the purchaser then returns
it to the appropriate local distributor.

In the event of a warranty claim,
please contact your dealer or the
nearest authorised After-Sales
Service office and produce both
accessories and proof of purchase.

GENERAL INSTRUCTIONS

Safety features

*

  Overflow valve with two pressure

switches

When reducing water volume at
pump head or with the servopress
control, the overflow valve will open
and part of the water will flow back
to the pump suction side.
If the handgun is closed thus
causing all the water to return to the
pump suction end, the pressure
switch at the overflow valve shuts off
the pump.
Reopening the handgun causes the
pressure switch at the cylinder head
to switch the pump back on again.
The overflow valve is set at the
factory and lead-sealed. Adjustment
can only be made by After-Sales
Service.

*

 Safety valve

The safety valve opens if the
overflow valve or pressure switch is
defective. The safety valve is set at
the factory and sealed. Adjustment
can only be made by After-Sales
Service.

*

 Low water protection

The low water protection stops the
burner being switched on in the
event of a lack of water. A strainer
stops the protection feature
becoming dirty and requires regular
cleaning.

*

  Motor protection switch

The motor protection switch
interrupts the circuit should
overloading occur.

Guidelines for liquid spraying
equipment

*

  The accident prevention

instructions (VBG 87) Working
with Jet Stream Equipment will
apply. In accordance with these
guidelines, high-pressure spraying
equipment must be checked at
least every 12 months by an
expert and the results of the
inspection recorded in writing.

Order governing boilers

*

  Test pressure and design of unit

comply with Order governing
boilers as per TRD. The water
content of the heating coil is less
than 10 litres. The boiler section of
the unit is thus not subject to
installation regulations. Local
building regulations are to be
heeded.

Summary of Contents for HDS 798 C

Page 1: ...HDS 798 C www karcher com 5 959 368 09 99 1 174...

Page 2: ...HDS 789 C 1 2 3 4 5 6 7 8 9 10 11 12...

Page 3: ...HDS 789 C 13 14 15 16 17 18 19 20...

Page 4: ...HDS 798 C Operating Instructions 5 Spare Parts List 14...

Page 5: ...tching on unit 8 Setting cleaning temperature 9 Setting operating pressure and flow rate 9 Measuring out the cleaning agent 9 Intended use 9 Cleaning 9 Operation with cold water 9 Operation with hot w...

Page 6: ...e all times Follow te maintenance instructions specified in the manual This product must connected to a power supply receptacle protected by a GFCI ground fault circuit interrupter If Replacement Of T...

Page 7: ...If oil level is approaching MIN mark fill up with oil as far as MAX mark Seal oil filler inlet Refer to technical data for oil grade Filling with scale inhibitor Fig 6 sample pack included with scope...

Page 8: ...wer plug Have power plug fitted by K RCHER AFTER SALES SERVICE or an authorised electrician Set selector switch to 0 Insert power plug Whenever socket is changed check direction of rotation of motor I...

Page 9: ...with oil separator Heed appropriate safety regulations for use at petrol stations or in other hazardous environments Working with high pressure nozzle Spray angle is crucial to efficiency of high pre...

Page 10: ...drained off completely Store unit in a frost free location Take unit out of service if frost free storage is not possible DISCONTINUATION OF USAGE In the event of lengthy periods of non use or if fros...

Page 11: ...off Motor overloaded overheated Set selector switch to 0 and allow motor to cool down for at least 5 min Have unit checked by After Sales Service if this does not remedy fault SCALE INHIBITOR indicat...

Page 12: ...ice and produce both accessories and proof of purchase GENERAL INSTRUCTIONS Safety features Overflow valve with two pressure switches When reducing water volume at pump head or with the servopress con...

Page 13: ...erating pressure cold hot water with standard nozzle supplied 32 150 bar Flow rate steam 360 l h Operating pressure steam with steam nozzle 4 766 023 max 32 bar Operating temperature Hot water max 90...

Page 14: ...HDS 798 C 14...

Reviews: