– 8
Change the oil in the high pressure pump.
For oil type refer to technical specifica-
tions.
Turn out the oil drain screw.
Drain the oil in a collection basin.
Screw in oil drain plug.
Fill in new oil slowly until the centre of
the oil level display.
Note
Air pockets must be able to leak out.
You can rectify minor faults yourself with
the help of the following overview.
If in doubt, please consult the authorized
customer service.
Risk of injury
Always switch off the appliance and pull out
the mains plug before care and mainte-
nance work.
Warning
Repair works may only be performed by the
authorized customer service.
The indicator lamps display the operating
states (green) and interruptions (red).
Reset:
Set the appliance switch to "0".
Wait for a while.
Set the appliance switch to "I".
Continuous green:
–
The appliance is now ready for opera-
tion.
1x blinking green:
–
Operational readiness has expired after
30 minutes.
–
The appliance has switched off after 30
minutes of continuous operation (safety
if the high pressure hose bursts).
Continuous red light:
–
Electrical problems in appliance
Pull out the mains plug.
Call Customer Service.
1x blinking red:
–
High pressure side is leaky
Check high pressure hose, hose con-
nections and hand spray gun for leaks.
2x blinking red:
–
Engine overload/overheat
Set the appliance switch to "0".
Allow device to cool down.
Set the appliance switch to "I".
–
Water pressure is too low
Ensure adequate water line pressure.
3x blinking red:
–
Fault in the voltage supply
Check main connections and mains fuse.
4x blinking red:
–
Power consumption is too high
Call Customer Service.
–
No power
Check whether the voltage indicated on
the type plate corresponds to the volt-
age of the socket.
Check the mains connection cable for
damages.
–
Indicator lamp is blinking green
Operational readiness period has expired.
Switch on/off the appliance again.
–
The water shortage fuse (option) was
triggered due to low water inlet pres-
sure.
The indicator lamp "lack of water" will il-
luminate.
Check water inlet pressure, minimum
value see "Specifications".
Turn the device switch to "0" and turn
on again to restart the system.
–
Motor overloaded/ over-heated or elec-
trical circuit breaker or winding protec-
tion switch has got released.
Switch off appliance and let it cool
down. Remove the cause of the prob-
lem. Turn on the appliance again.
monthly or after 500 operating hours
Oil change
Troubleshooting
Indicator lamp
Operating status display
Fault indication
Appliance is not running
21
EN
Summary of Contents for HD 16/15-4 Cage
Page 2: ...2...
Page 130: ...3 30 16 15 4 130 EL...
Page 131: ...4 HD 25 15 4 16 15 4 Cage T IEC 60364 1 1 10 m 4 mm2 10 30 m 6 mm2 131 EL...
Page 133: ...6 Power 25 Power 133 EL...
Page 134: ...7 30 2 3 0 134 EL...
Page 135: ...8 135 EL...
Page 136: ...9 3 0 1x 30 30 1x 2x 0 500 136 EL...
Page 137: ...10 3x 4x 0 3 137 EL...
Page 154: ...3 30 HD 16 15 4 154 RU...
Page 155: ...4 HD 25 15 4 4 HD 16 15 4 Cage IEC 60364 1 1 10 4 2 10 30 6 2 155 RU...
Page 157: ...6 I Power 25 Power 157 RU...
Page 158: ...7 30 2 3 0 158 RU...
Page 159: ...8 159 RU...
Page 160: ...9 3 0 I 1x 30 30 1 2 0 I 500 160 RU...
Page 161: ...10 3 4 0 3 161 RU...
Page 256: ...3 30 HD 16 15 4 256 BG...
Page 257: ...4 HD 25 15 4 HD 16 15 4 Cage IEC 60364 1 1 10 4 2 10 30 6 2 257 BG...
Page 259: ...6 I 25 259 BG...
Page 260: ...7 30 2 3 0 260 BG...
Page 261: ...8 T o 261 BG...
Page 262: ...9 3 0 I 1x 30 30 1x 2x 0 I 3x 500 262 BG...
Page 263: ...10 4x 0 3 263 BG...
Page 302: ...3 EN 12729 BA 30 HD 16 15 4 302 UK...
Page 303: ...4 HD 25 15 4 4 HD 16 15 4 Cage IEC 60364 1 303 UK...
Page 305: ...6 I 25 305 UK...
Page 306: ...7 30 2 3 0 306 UK...
Page 307: ...8 307 UK...
Page 308: ...9 3 500 308 UK...
Page 309: ...10 0 I 1x 30 30 1x 2x 0 I 3 4x 0 309 UK...
Page 313: ......
Page 314: ......
Page 315: ......
Page 316: ...http www kaercher com dealersearch...