background image

8

English

Batteries

Recommended battery sets BD 70/75

* Minimum volume of battery charging room
** Minimum air flow between battery charging room and
environment
When installing for the first time, an additional battery in-
stallation set is required:
1 2.638-198.0
2 2.638-162.0
3 2.638-106.0

Recommended battery sets BD 80/100

* Minimum volume of battery charging room
** Minimum air flow between battery charging room and
environment
When installing for the first time, an additional battery in-
stallation set is required:
1 2.638-162.0
2 2.638-106.0
3 2.638-197.0

Low-maintenance batteries (wet batteries)

DANGER

Refilling discharged batteries with water

Danger of acid burns from escaping acid, destruction of 
clothes
Wear safety goggles when handling the batteries.
Observe the applicable regulations.
Immediately rinse off any splashed acid from the skin or 
clothes using copious amounts of water.

ATTENTION

Using water with additives

Defective batteries, loss of warranty claim
Top up the batteries using only distilled or desalinated wa-
ter (EN 50272-T3).
Do not use any foreign additives, so-called enhancing 
agents, because this will invalidate the warranty.
1. Add distilled water one hour before the charging pro-

cess comes to an end. Observe the correct acid level
according to the battery label.
All cells must produce gas at the end of the charging
process.

Maintenance-free batteries (AGM and gel batteries)

ATTENTION

Risk of damage when opening AGM and gel batteries!

AGM and gel batteries are maintenance-free and have a 
closed battery housing. Refilling them with distilled water 
or battery acid is not possible and is not necessary. Open-
ing or drilling the battery housing will damage an AGM or 
gel battery and it will have to be replaced.
Do not open the battery housing and do not drill any holes.
Do not cover the pressure relief valve and do not change it.
1. Only charge AGM and gel batteries using the specified

chargers, see chapter: 

 Charging the battery

.

Installing and connecting batteries

CAUTION

Removing and installing the batteries

Unstable machine position
Ensure that the machine is positioned stably when remov-
ing and installing the batteries.

ATTENTION

Incorrect connection polarity

Destruction of the control electronics
Take care to ensure the correct polarity when connecting 
the batteries.

ATTENTION

Deep discharge

Risk of damage
Charge the batteries before starting the device.
1. Drain the waste water.
2. Pivot the waste water tank upwards.
3. Place the battery in the device as shown. 

Important:

Push the batteries all the way back!

BD 80/100

:

170 Ah, 2.815-092.0
180 Ah, 2.815-101.0
240 Ah, 2.815-105.0
285 Ah, 2.815-095.0

1

Spacer

Description

Order no.

Volume 
(m

3

)*

Airflow (m

3

/

h)**

115 Ah - main-
tenance-free

2.815-091.0 

1)

1.98

0.792

170 Ah - main-
tenance-free

2.815-092.0 

2)

2.31

0.924

180 Ah - main-
tenance-free

2.815-101.0

 3)

4.785

1.914

Description

Order no.

Volume 
(m

3

)*

Airflow (m

3

/

h)**

170 Ah - main-
tenance-free

2.815-092.0 

1)

2.31

0.924

180 Ah - main-
tenance-free

2.815-101.0

 2)

4.785

1.914

240 Ah - main-
tenance-free

2.815-102.0 

2)

6.27

2.508

285 Ah - main-
tenance-free

2.815-095.0 

3)

11.88

4.752

Summary of Contents for BD 80/100 W Classic Bp

Page 1: ...BD 70 75 W Classic Bp BD 80 100 W Classic Bp 59688290 09 20 Register your product www kaercher com welcome English 3 Fran ais 15 Espa ol 29...

Page 2: ......

Page 3: ...they can harm the materials on the machine Do not vacuum up burning or smouldering objects GROUNDING INSTRUCTIONS This device must be grounded If it should malfunction or break down grounding provides...

Page 4: ...onnel and detailed procedures shall be provided Maintenance and inspection of the device shall be per formed in conformance with the following practices 1 a scheduled planned maintenance lubrication a...

Page 5: ...pping damage please notify your dealer Safety instructions Before using the device for the first time read and observe these operating instructions and the accompanying bro chure Safety instructions f...

Page 6: ...ve 2 Fluff filter 3 Float 4 Cleaning head 5 Brush replacement pedal 6 Push handle 7 Safety button 8 Waste water tank cap 9 Homebase retaining rail 10 Waste water tank 11 Battery 12 Fresh water filter...

Page 7: ...rds from the carton packaging and the safety board screwed across the pallet and fasten with particle board screws 1 Safety board 2 Squared timber 3 Reinforcement board 5 Push the squared timber unscr...

Page 8: ...M and gel batteries AGM and gel batteries are maintenance free and have a closed battery housing Refilling them with distilled water or battery acid is not possible and is not necessary Open ing or dr...

Page 9: ...upwards 5 Disconnect the device end cable from the negative ter minal at the battery 6 Disconnect the remaining cables from the battery 7 For BD 80 100 Remove the spacer s between the front batteries...

Page 10: ...nk filling hole can be used for measuring the detergent It is fitted with a scale on the inside Adjusting the water volume 1 Adjust the water volume via the regulating knob to suit the degree of conta...

Page 11: ...or emptying the waste water tank 1 Turn the working speed rotary knob to the desired value The speed is shown on the display during the adjust ment The display is shown in percentage of the maxi mum s...

Page 12: ...ater and fresh water Safety inspection maintenance contract You can agree on regular safety inspections or close a maintenance contract with your dealer Please seek advice on this Maintenance interval...

Page 13: ...esh water tank lock 2 Fresh water filter 3 Pull out the fresh water filter and rinse with clean water 4 Insert the fresh water filter 5 Fit the fresh water tank lock Note Ensure that the hose connecti...

Page 14: ...or contamination and clean if necessary 5 Clean the suction lips at the suction bar turn over or replace if necessary 6 Check that the cap on the waste water drain hose is closed 7 Check the adjustmen...

Page 15: ...ature max F C 122 50 122 50 Water pressure max psi bar 0 87 0 06 0 87 0 06 Aisle turn width in mm 61 1550 65 1650 Max working area slope 2 2 Suctioning Suction performance air quantity CFM l s 50 8 24...

Page 16: ...e Meinung Rate your product and tell us your opinion valuer votre produit et dites nous votre opinion Rese e su producto y d ganos su opini n www kaercher com welcome www kaercher com dealersearch Alf...