English 5.906-269.0 Rev. 00 (03/11)
89
Connect the charger to the batteries.
Connect the voltage meter and clip-on ammeter to
the batteries.
Plug in mains connector and switch on charger.
Determine the current and voltage measuring val-
ues after switching on the charger and record
them.
Determine the current and voltage measuring val-
ues after about 10 minutes and record them.
The measuring result of the I constant phase in the
main charge must be close to the manufacturer's val-
ues of the charger.
See typeplate of charger.
Charger data:
Regulated charge ID line IUI charger for mainte-
nance-free batteries
IUIa means:
I = constant current line
U = constant voltage line
I = constant current line recharging
a = automatic switch-off (transition to maintenance
charge)
9.4.17Test the charger
Appliance type:
Charge:
Manufacturer
daily:
Order number of appli-
ance:
After each use:
Serial number:
Weekly:
Purchase date:
When was the last
charge:
Are damages visible on the battery?
Performance values of the charger with the battery connected immediately after the start of the charging
process (maximum, continuous current value):
Charge voltage:
Volt
Charge current (constant current!):
Ampere
Performance values of the charger with the battery connected after approx. 10 minutes:
Charge voltage:
Volt
Charge current (constant current!):
Ampere
Volt/Zelle
Ampere
AGM / Fliesbatterie 2,4 / Gel 2,35
I-Konstantphase U-Konstantphase
Hauptladung
Nachladung Erhaltungsladung
Spannung
Strom
Zeit
AGM / Fliesbatterie 2,25 / Gel 2,3