Brushes do not turn
–
Check the electrical connection on the brush motor.
–
Check whether the brush rollers / disc brush is blocked / remove for-
eign matters / replace brush rollers / disc brushes.
–
Check/replace the toothed belt.
–
Check /replace the appliance switch with motor protection switch (Ep
only)
–
Check / replace control PCB.
Charger is not working
ventilator on charger does not
start up
–
Wiring "W9“ between the control and the charger is interrupted.
Appliance is not working
Indicator lamp for the battery
monitoring is continuously red
Indicator lamp of the control
blinks
–
Control PCB has become wet.
Dry the control PCB and the plug.