English 5.906-269.0 Rev. 00 (03/11)
45
6.8.2 Wet scrubbing (with vacuuming)
Initial use
Display
Battery: E...F
Shutting down
Switch the programme selector switch (S2) to position “wet scrubbing with vacuuming"
Drive switch (S4) switched off
Suction turbine (M2) active
Cleanspeed active ("Cleanspeed Edit" set to "1" in setup menu)
Suction turbine speed (M2) ("SUCTred Edit“ set to "1" in setup menu)
DOSE active, ("DOSE Edit" set to "1" in setup menu) (option)
Display
Battery: E...F
Red LED "Fault" is glowing continuous-
ly
After approx. 10 seconds of overload,
the following will be shut off
–
Brush motor
–
Solenoid valve water
–
Dosing pump detergent (optional)
Display
Brush overload
Red LED "Fault" is blinking
Switch the key switch off and perform
startup
Drive and brush motor
(M1 und M2) ready
Deadman switch (S3)
actuated?
No
Yes
Brush motor (M1) active
- Check the solenoid
valve.
Yes Brush motor overload?
No
(Option) switch for deter-
gent (S5) on?
No
Yes
Dosing pump (optional)
on
Continued on next page.