72
English 5.906-269.0 Rev. 00 (03/11)
8.2.3 Display setup manu (W Bp Pack)
Display parameter setup (exclusively for models with display and info button),
sequence and factory settings, 10/09
Parameter
Factory
setting
min:step:max
Remarks
Se-
quence
Service
access
Maschine
type:
R
1
BR 45/40BD 45/
40
Modell variant. With the BD, the FACT
operator menu is hidden, displayed for
BR.
1
X
Discharge
voltage: 21.0
V
21.0 V
19.0..0.122.5 V
Discharge final voltage at which all
units shut off to protect the battery.
The control display signals the required
battery charging by glowing RED.
2
X
Standby: 30
min
30 min
0min:30min:60mi
n
If a cleaning programme is preselected
and if no unit is running, the machine
will shut down into idle mode after this
time has elapsed.
For a new startup, the programme se-
lector switch must be set to "OFF" or a
key switch reset must be performed.
3
X
Suction trail:
10 s
10s
0s:5s:60s
Trail time of the suction turbine, if you
switch from one vacuum programme to
a programme without vacuuming or to
OFF.
4
X
Speed:---
3
00:01:05
Max. drive speed in transport mode,
v=0.67 km/h (n+1) n=number of bars.
5
X
Acceleration
ramp: 3
3
00:01:09
Acceleration of the drive motor when
starting, highest acceleration: 9
6
X
Brush ramp: 9 9
00:01:09
Acceleration of the brush motor, high-
est acceleration: 9
7
X
CleanSpd-
Edit: 1
1
0=N, 1=Y
Show CLEANSPEED menu.
8
X
SUCTred.Ed-
it: 1
1
0=N, 1=Y
Bit to activate the turbine speed opera-
tor menu.
0 = Speed adjustment hidden, turbine
works at 100% nominal speed
1 = speed adjustment is displayed.
9
X
DOSE-Edit: 1
1
0=N, 1=Y
Bit to activate the DOSE operator
menu.
0 = DOSE menu hidden, dose works at
1.0% fixed for Pack models
1 = DOSE menu is displayed.
10
X
Power driv-
ing: 15 A
15A
10 A:1 A:40 A
Max. regular power of the drive motor.
In case of overload, the power is limited
to the set up value for 30 seconds until
the shut-off with fault message occurs.
A new startup requires OFF or a key
switch reset.
11
X