108
English 5.906-269.0 Rev. 00 (03/11)
Suction turbine
fault=3
20
Overload
suction mo-
tor
Turn the programme
selector switch to the
position "Drive". Then
select the cleaning
programme once
more. If the fault re-
curs, call customer
service.
3*
blinking
X
X
Brush overload! 21
Overload on
brush motor
Turn the programme
selector switch to the
position "Drive". Then
select the cleaning
programme once
more. If the fault re-
curs, call customer
service.
3*
blinking
X
X
Valve fault=1
22
Short circuit
in solenoid
valve
Call customer service. 1*
blinking
X
X
X
Check battery
voltage
23
Too high
battery volt-
age while
charging
Disconnect the charg-
er from the socket. It
can be cleaned again.
Inform Customer
Service at any rate.
4*
blinking
Driving motor
fault=1
24
Short circuit
in driving
motor
1*
blinking
X
X
X
Drive motor
fault=2
25
Drive motor
wire break-
age
2*
blinking
X
X
X
Pcb. Fault=4
26
PCB defec-
tive
Perma-
nent
light
X
X
X
Wapu.Fault=3
30
Water pump
overload
Turn the programme
selector switch to the
position "Drive". Then
select the cleaning
programme once
more. If the fault re-
curs, call customer
service.
1*
blinking
X
X
X
X
Drive motor
fault=3
31
Overload
drive motor
Turn the programme
selector switch to the
position "Drive". Then
select the cleaning
programme once
more. Do not drive on
INCLINES > 2 % with
this appliance. If the
fault recurs, call cus-
tomer service.
3*
blinking
X
X
X
Display
Er-
ror
cod
es
Fault
source
Measures
LED
dis-
play
fault
Driv-
ing
possi-
ble
Vacu-
uming
possi-
ble
Scrub-
bing
possi-
ble
Polish-
ing
possi-
ble