![background image](http://html1.mh-extra.com/html/karcher/b-80-w-bp/b-80-w-bp_service-manual_3579740020.webp)
20
English 5.906-468.0 Rev. 00 (02/09)
Î
Unscrew locking screws.
Î
Remove the filling system from the tank.
Î
Grease the seal ring when installing the new filling system.
1
Filling system
2
Fastening screws (4x), filling system
3
Fresh water inlet into the fresh water reservoir
4
Float
5
Switch-off valve
To improve the vacuuming result on tiled floors the vacuum bar can
be turned to an oblique position of up to 5°.
Î
Release the wing screws.
Î
Turn the vacuum bar into the respective horizontal position.
Î
Retighten the wing screws.
If the vacuum result is unsatisfactory the inclination of the straight
vacuum bar can be modified.
Î
Loosen the wing nuts.
Î
Tilt the vacuum bar accordingly.
Î
Retighten the wing screws.
1
Wing screws (2x), setting of the tilting position
2
Wing screws (2x), setting of the horizontal position
5
Basic settings and service procedures
5.1
Replace filling system
5.2
Setting the vacuum Bar