English 5.906-468.0 Rev. 00 (02/09)
17
The flowmeter measures the set water volume, after that the cor-
responding volume of detergent is metered in by switching on the
detergent pump.
1
Detergent dosing pump (DOSE)
2
Cover, detergent pump
3
Cap, pump motor
4
Pump outlet
5
Pump input
6
Connection cables, detergent pump
7
Detergent pump (M6)
8
Transport rotor
9
Transport hose
10 Transport rolls
11 Flowmeter
12 Control cable, flowmeter
13 Motor, detergent pump
14 Control board
The brush head is switched on and off by lowering and raising it.
Î
Raise: Press the pedal downward and lock it towards the right.
Î
Lower: Press the pedal downwards; move it to the left and re-
lease it upward.
The brush head will automatically start up as soon as the appliance
is driven forward/backwards.
The desired brush contact pressure is adjusted by means of the lever.
The setting is adjusted in several detents. With each detent, by which
the lever is pressed down, the brush contact pressure is reduced.
Note
Only use the lever while the brush head is lowered. When moving
the lever while the brush head is raised, there can be injuries by the
lever flying upwards.
While the brush head is raised, the press spring on the brush head
pickup is compressed.
If the brush head is lowered, the press spring is decompressed and
presses the brush head onto the floor.
When the brush head is lowered, the microswitch switches on the
brush motors.
If the brush head is raised, the microswitch turns the brush motors
back off.
1
Foot lever for raising/lowering the brush head
2
Lever for adjusting the brush contact pressure
3
Press spring, compressed
4
Press spring, decompressed
5
Microswitch (S7), brush motors (M1, M2) ON/OFF