Page 77 of 101
DWG ID: 181-0101-00A
Date: 2003-09-26
callsign on the list (if there is not, the TALON responds with “EH?” and returns you to
the command prompt). Similarly, you can remove a single callsign (-callsign) from the
list. And to remove all items from the current list, enter LLIST NONE.
A callsign entered without a SSID will match any SSID of that callsign. To match a
specific SSID only, enter the callsign with that SSID: for example, callsign-n, where n =
0-8191.
LOCATION
Immediate
Displays the current location information.
MALL {ON | OFF}
default ON
When ON, monitored packets include connected and unconnected packets between other
stations. If OFF, only other station’s unconnected packets (UI frames) will not be
displayed.
This is a useful arrangement when stations are talking as a group in an unconnected
configuration.
See also: monitor
MAXFRAME n
(n = 1 - 7)
default 4
MAXFRAME sets an upper limit on the number of unacknowledged information packets,
which can be outstanding at any one time. The TALON will send MAXFRAME number
of packets in a single transmission, if they are available.
See also: paclen
MAXUSERS n
(n = 0-10)
default 1