19 of 32
© 2003
D 369e - 06/03
Control
Adjust
Menu (2 of 2)
NONE, STRT
Default = NONE
0:10 to 3:00 hr
Default = 0:30 hr
0:30 to 4:00 min
Default = 3:00 min
0:10 to 2:00 min
Default = 0:30 min
Section
LTD
INST ADV
USER
B3
A1
A1
B1
Item Field
Description
Access
Level
Range
Actual
Setting
The time the heating zones assigned to the
cooling group must be off before cooling
operation is allowed.
COOL MOD
≠
NONE
Enables or disables the Optimum Start feature
for the cooling system.
COOL MOD = CTRL
The time required for a thermal zone valve to
open.
any
ZNi OUTP = THRM
(i
= 1. . . . . 6)
The time required for a thermal zone valve to
close.
any
ZNi OUTP = THRM
(i
= 1. . . . . 6)
OFF, 0:10 to 4:00 min
Default = 0:30 min
5:00 to 30:00 min
Default = 15:00 min
30 to 240 hr, OFF
Default = 70 hr
A1
A1
A1
The maximum length of time that a zone device
and the system pump continues to operate
after a heat demand is removed.
The cycle length used for heating operation.
The frequency with which the control exercises
the pumps and valves that are operated by the
control.
Zone
Adjust
Menu (1 of 2)
PUMP, VLV, THRM
Default = VLV
ONE, TWO
Default = ONE
NONE, CG
Default = CG
NONE, CTRL
Default = NONE
Section
LTD
INST ADV
USER
A2
A3
B1
C
A1
Item Field
Description
Access
Level
Range
Actual
Setting
The type of zoning device that is to be used.
(RTU or indoor sensor is present)
Selects single stage or two stage operation.
(RTU or indoor sensor is present in even zone,
and RTU is not present in the preceding odd zone)
Selects if this zone is part of the cooling group.
(RTU or indoor sensor present, Zone 1 to Zone 5)
COOL MOD
≠
NONE
Selects if this zone is operated on the control
schedule.(Indoor sensor present)
DIP switch =
Setback
Note:
The Zone Adjust menu is repeated for each zone that an RTU or indoor sensor is connected to. The Zone Adjust menu is
indicated by
Adjust
in the left hand side oaf the display, and
Zone
followed by the zone number in the bottom of the display.