ACD320user manual
Function parameters list
- 50-
detection delay
Function
Code
Name
Set range
Default
Value
Modifi
cation
Serial
No
F7.26
PID
range
0
~
50.0
10.0
○
175
F7.27
Operation when set
frequency is lower
than
low
limit
frequency
0:Run at lower limit Freq.
1:Run at
0Hz.
0
○
176
F7.28
Selcet
sleeping
signal
0: Select internal sleeping signal
1: Select external sleeping signal
2: Internal and external signal are valid at the same
time.
0
○
177
F7.29
Simple
PLC
running mode
1: Run circularly.
2: Stop after running for one circulation.
3: Run at the selected speed after running for one
circulation.
1
○
178
F7.30
The
0
st
step
running time.
0
~
999.9
0
○
179
F7.31
The
1
st
step
running time.
0
~
999.9
0
○
180
F7.32
The
2
nd
step
running time.
0
~
999.9
0
○
181
F7.33
The 3
rd
step running time.
0
~
999.9
0
○
182
F7.34
The
4
th
step
running time.
0
~
999.9
0
○
183
F7.35
The
5
th
step
running time.
0
~
999.9
0
○
184
F7.36
The
6
th
step
running time.
0
~
999.9
0
○
185
F7.37
The
7
th
step
running time.
0
~
999.9
0
○
186
F7.38
Simple
PLC
selection record or
not when power
off.
0:
Record when power off
1: No record
when power off.
0
○
187
F7.39
Simple
PLC
running time unit.
0:s
1:min
0
○
188
F7.40
Failure shield
BIT0: Module protection shield
0:Invalid 1: Valid
1
0
×
189
BIT1: Soft overcurrent shield.
0:Invalid 1: Valid
2
BIT2: Over-voltage shield.
0:Invalid 1: Valid
4