ACD320 user manual
Parameter Description
- 102-
F7.30
The 0
st
step running time.
0
~
999.9
0
F7.31
The 1
st
step running time.
0
~
999.9
0
F7.32
The 2
nd
step running time.
0
~
999.9
0
F7.33
The 3
rd
step running
time.
0
~
999.9
0
F7.34
The 4
th
step running
time.
0
~
999.9
0
F7.35
The 5
th
step running
time.
0
~
999.9
0
F7.36
The 6
th
step running
time.
0
~
999.9
0
F7.37
The 7
th
step running
time.
0
~
999.9
0
In simple PLC run mode, PLC run and skip the step whose running time is set to be 0, and
simple PLC run will not operate if all the set is 0.
When PLC run from 0th to the 7th step, the parameter corresponding to the frequency set is
F4.29~F4.36.
Function Code
Name
Setting Range
Default
Value
F7.38
PLC selection record or
not when power off.
0: Record when power off
1: No record when power
off
0
PLC selection record or not when power off means whether to record the running status
before power off.
Function
Code
Name
Setting Range
Default Value
F7.39
running time unit
0:s
1:min
0
F7.40
Failure shield
0: Effective
1:Ineffective
0
Discription of failure shield display:
Display content when stop
Code
BIT0: Module protection shield
0:Invalid 1: Valid
1
BIT1: Soft overcurrent shield.
0:Invalid 1: Valid
2
BIT2: Over-voltage shield.
0:Invalid 1: Valid
4