![K&R ACD320 Series User Manual Download Page 44](http://html1.mh-extra.com/html/kandr/acd320-series/acd320-series_user-manual_3099779044.webp)
ACD320user manual
Function parameters list
- 39-
F0.11
Carrier frequency
setting
1.0
~
15.0kHz
Set by
model
○
11
F0.12
Functional
parameters
restoration
0: NO operation
1: Restore default value
2: Delete failure records
0
×
12
F0.13
AVR selection
0: Invalid
1: Valid all the time
2: Invalid during deceleration
1
○
13
F0.14
Star t Mode
0: Direct start
1: DC braking first and then start
0
×
14
F0.15
Start frequency
0.50
~
10.00Hz
0.00Hz
○
15
F0.16
Hold time of start
frequency
0.0
~
50.0s
0.0s
○
16
F0.17
Braking current
before start ing
0.0
~
150.0%
0.0
○
17
F0.18
Braking time before
start ing
0.0
~
50.0s
0.0s
○
18
F0.19
Stop Mode
0: DECEL Stop
1: Free run Stop
0
○
19
F0.20
Beginning
Frequency of
braking
0.00
~
F0.04
0.00Hz
○
20
F0.21
Waiting time of
braking
0.0
~
50.0s
0.0s
○
21
F0.22
DC braking current 0.0
~
150.0%
0.0
○
22
F0.23
DC braking time
0.0
~
50.0s
0.0s
○
23
F0.24
Dead time between
forward and
reverse
0.0
~
3600.0s
0.0s
○
24
F0.25
Terminal comma nd
Protection when
power on
0: Terminal command invalid when power on
1: Terminal command valid when power on
0
○
25
F1 Motor Parameter
F1.00
Inverter model
0: G model
1: L model
0
×
26
F1.01
Motor rated power 0.4
~
900.0kW
Set by
model
×
27
F1.02
Motor rated
frequency
0.01Hz
~
F0.04
50.00Hz
×
28
F1.03
Motor rated speed
0
~
36000rpm
Set by
model
×
29
F1.04
Motor rated voltage 0
~
460V
Set by
model
×
30