Parameter Description
- 101-
Function Code
Name
Setting Range
Default
Value
F7.27
Operation when set
frequency is lower than
low limit frequency
0: Run at lower limit Freq.
1: Run at 0Hz.
0
Select the run status of the inverter when the set frequency is lower than low limit
frequency.
The function can be selected to stop the inverter in order to avoid the motor long-term
running at a low speed.
Function Code
Name
Setting Range
Default
Value
F7.28
Select sleeping signal
0: Select internal sleeping
signal
1: Select external sleeping
signal
2: Internal and external
signal are valid at the
same time.
0
Select internal sleeping signal, please refer to F7.21
、
F7.22.
Select external sleeping signal, please refer to the set of corresponding MI terminal
(
F2.01
~
F2.06
)
.
2:Internal and external signal are valid at the same time, sleeping is effective as long as one
in internal sleeping signal and external sleeping signal is effective.
Function Code
Name
Setting Range
Default
Value
F7.29
Simple PLC run
1: Run circularly.
2: Stop after running for
one circulation.
3: Run at the final value
after running for one
circulation.
1
When F0.03=7, simple PLC (program) run is effective.