ZEUS-VD INSTALLER’S MANUAL
9.16
ZEUS4-VD SET-UP PARAMERTERS
⇒
CRE
–
repetition of calling sequences. With the number from 1 to 99 we define how often
the sequence is repeated in case the number is busy or not answered. The default value is set
to number “3”.
⇒
HTN
–
hidden telephone number. This function (“0” value) is used in order to conceal the
telephone number of the ZEUS4-VD device. The default value is set to “1” which means
that the number is displayed.
⇒
SCV
–
SIM card validity. The period of valid operating time varies with different GSM
network providers. The value can be programmed from 1 to 360 days. The default value
does not presume any kind of expiry warning.
After the SIM refill is necessary sending the SMS ;SCV=XXX; to the ZEUS4 and reset the
counter.
;SCV=XXX; when XXX are in days which are not the same for all GSM providers. For
example in Slovenia SCV are 90 and in Italy 360 days.
NOTE:
The parameter SCV must be sending by SMS command and should not be programmed
direct on SIM card!
⇒
TST –
A test SMS is sent periodically. The ZEUS4-VD can send the test message in the
interval ranging from 1hour up to 240 hours.
Example: if the TST value is set to 12, the numbers linked to “LN7” get a test message
every 12 hours.
⇒
MNF -
When is necessary to fix the GSM network to one provider we can use the MNF
parameter. The MNF parameter will switch automatic network searching to manual.
For example:
MCC/MNC code for Simobil is 29340, Mobitel is 29341, TIM is 22201, and Vodafone Italy
is 22210;
More information’s about national MCC/MNC codes you can get here:
http://www.activexperts.com/activsms/networkcodes/
⇒
RAN –
Number of rings before ZEUS4-VD will answer. With this command you can set
the ring counter and unit will automatically answer after n ring programmed with this
parameter. The default value is 5 rings.
Page 26
⇒
LNG –
the command will switch between the pre-programmed languages’:
Example:
0= English, 1= Italian, 2 = Slovenian, 3 Croatian, 4= Dutch
The default language is English.