ZEUS-VD INSTALLER’S MANUAL
13
CHECKING THE INPUT STATUS
You can get the information's about inputs status on two different ways:
⇒
Call in the ZEUS4-VD and use DTMF commands
⇒
Send the SMS command and get back the SMS with inputs status
13.1
CHECKING THE INPUT STATUS BY DTMF
After the short beep press the DTMF command. Response with 1 beep means that the input is in
alarm state and response with 3 beep means that the input is in normal (stand-by) state.
51
Input 1 status checking (1 beep=alarm, 3 beeps=normal)
52
Input 2 status checking (1 beep=alarm, 3 beeps=normal)
53
Input 3 status checking (1 beep=alarm, 3 beeps=normal)
54
Input 4 status checking (1 beep=alarm, 3 beeps=normal)
13.2
CHECKING THE INPUT STATUS BY SMS (INS)
Command
;INS;
Sending this command to the ZEUS4-VD you will get the replay SMS with all Inputs status. The
replay can be:
;INS(1-4)=(OPEN-ON) – alarm loop is open and the input is in the alarm state
;INS(1-4)=(OPEN-OFF) – alarm loop is open and the alarm input is in the idle state
;INS(1-4)=(LOW-ON) – alarm loop is close on GND and the input is in the alarm state
;INS(1-4)=(LOW-OFF) – alarm loop is close on the GND and the alarm input is in the idle state
;INS(1-4)=(HGH-ON) – alarm loop is close on +12VDC and the input is in the alarm state
;INS(1-4)=(HIGH-OFF) – alarm loop is close on the +12V and the alarm input is in the idle state
;SYS= ON;
;SYS= OFF;
Page 34