background image

fig. D shows mounting it to the Top Table PRO 

basic support.

Subsequently attach the lights (1) to the vertical arms (2)
(fig. E).

Make sure that the mains voltage corresponds to the op-
erating voltage given on the type plate of the mains adapter
(5).

Connect the mains adapter (5) with both lights (1) by means
of the splitter cable (23) and the extension cables (13) (see
connecting scheme fig. N).

Centre the soft screens (4) in longitudinal direction to pro-
vide for sufficient ventilation of the LEDs.

Clip the extension cables (13) on to the vertical arms (2) by
means of the cable clips (14) (fig. F).

Now connect the mains adapter (5) to the mains using the
mains lead (6). The indicator LED (24) of the mains adapter
lights up.

5. Initial operation

Switch on the lights (1) by pressing shortly the respective
control dial (15) (fig. G). Now you can adjust the brightness
of each light individually with the correspondent control 
dial (15). The display (16) shows the brightness setting in 
1 %-steps from 10 % up to 100 %.

If you want to adjust the brightness of both lights syn-
chronously, connect the lights with the light synchro cable
(17). Insert the plugs (19) into the respective port (20) (fig.
H); they click into place audibly. Now any of the control di-
als (15) can be used to adjust the brightness of both lights
combined.  

If you want to control the brightness of the lights separately
again, disconnect the lights by unplugging one or both
plugs (19) from the port(s) (20). Push the latch release (18)
towards the plug (19) to unlock the plug. Do not apply force
when releasing the plug to prevent damage of the port or
plug.

Switch off each light separately when not in use by press-
ing the respective control dial (15) shortly.

6. Adjustments

The lighting unit can be adjusted in a variety of ways (see
fig. I – L). To adjust it, release the respective fastening
screw (22), (12) or (7) and tighten it again.

7. Removing/Inserting soft screen

The lights are equipped with a 

soft screen

(4) for particular

soft light. If this is not required and if there is a need for
more light, the lights can also be operated without the soft
screens. To remove the soft screen camber it at the narrow
side a bit outwards and remove it – starting from the cam-
bered narrow side – from the guide slot of a long side (fig.
M).

To reinsert a soft screen, place it in the guide slot of one
long side, then camber it on one narrow side a bit outwards
and push it – starting from the cambered narrow side – into
the guide slot of the opposite long side. It is irrelevant which
side of the soft screen faces outwards.

polarizing foil

(optional accessory) can also inserted or

removed in the same way. The polarizing foil can be used
with or without the soft screen. When used with the soft
screen the polarizing foil must be placed at the outside.  

8. Maintenance and care

The lights are maintenance-free. Make sure that the soft
screens (4) are free of stains and dirt. If necessary remove
these before operation.

Clean the devices with a soft dry cloth. On no account use
petrol or other solvents.

9. Specifications

Lights

LED arrays:                                         2 x 192 SMD LEDs

Color temperature:                            5600 K

Color rendition index:                       CRI = 95

LED angle of radiation:                    100°

Max. illumination*

with soft screen:                             5000 lux
w/o soft screen:                             5600 lux

Max. power of LEDs:                        2 x 38.4 W

Operating voltage:                            24 V  

Light emitting area of one light:         41.5 x 16.5 cm 

(16.3 x 6.5 in.)

Mains adapter

Input:                                                    100-240 V, 50/60 Hz
Output:                                               24 V, 6 A

_______

* based on uniform illumination of a 16.5 x 11.5 in. flat subject

10. Accessories

5256  Clamp bases. For attaching the RB 520 AS surface

lighting unit to regular boards up to 48 mm (1.9 in.)
thickness. 2 pieces. 

5641  Polarizing foils, 2 pieces.

Right reserved to make technical modifications. 

All specifications are approximate.

Disposal Instructions

Dispose an unserviceable product in
accordance of the relevant statutory
regulations.

5279Bedien_0819.qxp_5279Bedien  28.10.19  09:44  Seite 6

Summary of Contents for RB 520 AS

Page 1: ...ode d emploi Instrucciones de manejo Istruzioni per l uso Kaiser RB 520 AS LED Beleuchtungseinrichtung LED Surface Lighting Unit clairage LED Unidad de iluminaci n LED Illuminatore LED 5279 5279Bedien...

Page 2: ...K L M N B I I nicht ben tigt not needed 4 5 3 2 1 7 6 10 11 8 13 12 9 14 15 16 17 20 19 18 21 22 23 2 3 8 3 2 8 7 10 8 2 1 2 13 7 12 4 5 6 21 20 17 19 13 1 4 24 5279Bedien_0819 qxp_5279Bedien 28 10 1...

Page 3: ...ch nicht bestimmungsgem en oder falschen Gebrauch ent standen sind 2 Sicherheitshinweise Bitte beachten Sie die folgenden Sicherheitshinweise WARNUNG Trennen Sie die Ger te Leuchten Netzteil bei Nicht...

Page 4: ...ehe Abb I L Lockern Sie dazu die jeweilige Schraube 22 12 oder 7 und ziehen Sie sie anschlie end wieder fest 7 Softscheibe entnehmen einsetzen Die Leuchten sind mit einer Softscheibe 4 f r besonders w...

Page 5: ...Safety instructions Please observe the following safety instructions WARNING Disconnect the devices lights mains adapter from the mains if not in use or before cleaning Keep the products away from chi...

Page 6: ...hten it again 7 Removing Inserting soft screen The lights are equipped with a soft screen 4 for particular soft light If this is not required and if there is a need for more light the lights can also...

Page 7: ...s provoqu s par une utilisation non conforme de ce produit 2 Consignes de s curit Merci de respecter les consignes de s curit suivantes AVERTISSEMENT D connectez du secteur l alimentation du produit l...

Page 8: ...tes mani res voir sch ma fig I L Pour l ajuster d vissez les vis de serrage respectives 22 12 ou 7 et resserrez les une fois que vous avez atteint l orientation souhait e 7 Retirer Replacer les diffus...

Page 9: ...Kaiser no se responsabiliza de cualquier da o causado por uso no previsto o incorrecto 2 Instrucciones de seguridad Por favor observe las siguientes instrucciones de seguri dad ATENCI N Desconecte los...

Page 10: ...I L Para ajustarla libere el correspondiente tornillo de fijaci n 22 12 o 7 y apri telo de nuevo 7 Insertar y retirar la pantalla difusora Las luces est n equipadas con una pantalla difusora 4 para l...

Page 11: ...di sicurezza Si prega di osservare le seguenti istruzioni di sicurezza AVVERTENZA Scollegare i dispositivi luci adattatore di rete dalla rete se non utilizzati o prima della pulizia Tenere i prodotti...

Page 12: ...e rispettive viti di fis saggio 22 12 o 7 e serrare nuovamente 7 Rimozione Inserimento del soft screen Le luci sono dotate di un soft screen 4 per particolari luci soffuse Se non serve e se necessaria...

Reviews: