Kaiser Fototechnik RB 520 AS Operating Instructions Manual Download Page 5

ENGLISH

(1) Light

(2) Vertical arm

(3) Articulated joint base 

(4) Soft screen

(5) Mains adapter

(6) Mains lead

(7) Fastening screw for vertical arm

(8) A8.4 washer

(9) Fastening screw for mounting the articulated joint

base to a Copylizer

(10) M8x16 hexagon socket screw

(11) ø 32 mm washer for mounting the articulated joint

base to a shooting table

(12) Fastening screw for the light

(13) Extension cable

(14) Cable clip

(15) Control dial for brightness and ON/OFF

(16) Display

(17) Light synchro cable 

(18) Latch release

(19) Plug of light synchro cable

(20) Port for light synchro cable

(21) Port for power supply

(22) Locking screw for the light

(23) Splitter cable

(24) Control LED

Prior to using your RB 520 AS surface lighting unit, please
read these instructions carefully. Keep them safe to have
them at hand at any time. If you pass the devices on to
somebody else, always include these instructions.

1. Intended use

The RB 520 AS surface lighting unit is marketed exclusively
for the purpose of illumination for image capture. It is not
intended for household lighting.

The lighting unit is equipped with articulated joint bases for
attachment to the exe.cutive LED Copylizer (5215), the
exe.cutive LED Illumina Base Plate (5244) or the TopTable
PRO Basic Support (5921). Supplemented with the 5256
Clamp Bases – available as an accessory – it can also be
attached to boards up to 48 mm (1.9 in.) thickness.  

Use the RB 520 AS surface lighting unit only as described
in these instructions. Any other use has to be considered
as not as intended and can result in material damage or
physical injury. The RB 520 AS surface lighting unit is not
a toy.

Kaiser takes no responsibility for damages caused by not
intended or incorrect use.

2. Safety instructions

Please observe the following safety instructions:

WARNING!

Disconnect the devices (lights / mains adapter) from the
mains if not in use or before cleaning.

Keep the products away from children.

Do not put the devices into operation, if housing, plugs or
cables are damaged.

Do not disassemble or modify the devices. Repairs must
only be carried out by qualified persons.

CAUTION!

Only use the lighting unit with parts designed for it.

Use the devices only in dry rooms.

Keep the devices away from water and other liquids and
from combustible materials.

Make sure that the devices are not covered during opera-
tion.

Do not use or store the devices at places with extremely
high air humidity or at extremely hot places. Keep the de-
vices away from direct solar radiation.

Let the devices cool down before boxing them.

3. Check devices and scope of supply

When unpacking the devices for the first time, please
check if the scope of supply is complete. It comprises

2 Lights (1) with soft screen (4)

2 Fastening screws (12) for the lights

2 Vertical arms (2)

1 Accessory kit:

2 Articulated joint bases (3)
4 M8x16 hexagon socket screws (10)

(for mounting to a Copylizer only 2 screws are
necessary)

2 A8.4 washers (8)
4 ø 32 mm washers (11) (for mounting to the

TopTable PRO basic support)

1 Hex-wrench SW6 (6 mm)

2 Fastening screws (9) (for mounting to a

Copylizer)

2 Fastening screws (7) for vertical arms
4 A8.4 washers (8)

1 Mains adapter (5)

1 Mains lead (6)

1 Splitter cable (23)

2 Extension cables (13)

1 Light synchro cable (17)

4 Cable clips (14)

Check also, if the devices are damaged by extraneous
causes. If this is the case, do not take the devices into op-
eration.

4. Assembly / Connecting the mains adapter

Attach the articulated joint bases (3) and the vertical arms
(2) as shown in fig. C or D:

fig. C shows mounting it to a Copylizer or 

to a illumina base plate,

5279Bedien_0819.qxp_5279Bedien  28.10.19  09:44  Seite 5

Summary of Contents for RB 520 AS

Page 1: ...ode d emploi Instrucciones de manejo Istruzioni per l uso Kaiser RB 520 AS LED Beleuchtungseinrichtung LED Surface Lighting Unit clairage LED Unidad de iluminaci n LED Illuminatore LED 5279 5279Bedien...

Page 2: ...K L M N B I I nicht ben tigt not needed 4 5 3 2 1 7 6 10 11 8 13 12 9 14 15 16 17 20 19 18 21 22 23 2 3 8 3 2 8 7 10 8 2 1 2 13 7 12 4 5 6 21 20 17 19 13 1 4 24 5279Bedien_0819 qxp_5279Bedien 28 10 1...

Page 3: ...ch nicht bestimmungsgem en oder falschen Gebrauch ent standen sind 2 Sicherheitshinweise Bitte beachten Sie die folgenden Sicherheitshinweise WARNUNG Trennen Sie die Ger te Leuchten Netzteil bei Nicht...

Page 4: ...ehe Abb I L Lockern Sie dazu die jeweilige Schraube 22 12 oder 7 und ziehen Sie sie anschlie end wieder fest 7 Softscheibe entnehmen einsetzen Die Leuchten sind mit einer Softscheibe 4 f r besonders w...

Page 5: ...Safety instructions Please observe the following safety instructions WARNING Disconnect the devices lights mains adapter from the mains if not in use or before cleaning Keep the products away from chi...

Page 6: ...hten it again 7 Removing Inserting soft screen The lights are equipped with a soft screen 4 for particular soft light If this is not required and if there is a need for more light the lights can also...

Page 7: ...s provoqu s par une utilisation non conforme de ce produit 2 Consignes de s curit Merci de respecter les consignes de s curit suivantes AVERTISSEMENT D connectez du secteur l alimentation du produit l...

Page 8: ...tes mani res voir sch ma fig I L Pour l ajuster d vissez les vis de serrage respectives 22 12 ou 7 et resserrez les une fois que vous avez atteint l orientation souhait e 7 Retirer Replacer les diffus...

Page 9: ...Kaiser no se responsabiliza de cualquier da o causado por uso no previsto o incorrecto 2 Instrucciones de seguridad Por favor observe las siguientes instrucciones de seguri dad ATENCI N Desconecte los...

Page 10: ...I L Para ajustarla libere el correspondiente tornillo de fijaci n 22 12 o 7 y apri telo de nuevo 7 Insertar y retirar la pantalla difusora Las luces est n equipadas con una pantalla difusora 4 para l...

Page 11: ...di sicurezza Si prega di osservare le seguenti istruzioni di sicurezza AVVERTENZA Scollegare i dispositivi luci adattatore di rete dalla rete se non utilizzati o prima della pulizia Tenere i prodotti...

Page 12: ...e rispettive viti di fis saggio 22 12 o 7 e serrare nuovamente 7 Rimozione Inserimento del soft screen Le luci sono dotate di un soft screen 4 per particolari luci soffuse Se non serve e se necessaria...

Reviews: