Operation Instructions for Air-to-water Heat Pump Split ECO HOME
Operation Instructions for Split Versati
7
SPLIT TYPE
19
Thermostat
Thermostat
Air/Without/
Air+hot water
Without
This setting cannot be changed
from “Air” to “Air+hot water”
directly but via “Without” this option
and the unit will go to Without
status. Meanwhile, the control
will send out “Without” command
for consecutive 40 seconds (it is
longer than the communication
error, and the “On” command
can be performed only when 40
seconds have been expired.
When it set to “Air+hot water”, “hot
water” can be performed even
though the thermostat is off.
20
Assistant heater
Assis. Heater
1/2/Off
Off
/
21
Other heater
Other heater
With/Without
Without
/
22
Chassis heater
Chassis heater
On/Off
On
/
23
Tank heater
running
Tank heater
On/Off
Off
When the water tank is available,
this setting is adjustable; when it is
unavailable, it will be reserved.
When it is set to be “Off” and the
solar kit is available, the water tank
temperature will be adjustable;
when the solar kit is unavailable,
the upper limit of the water tank
temperature should be set to
50 .
24
Solar kit-
antifreeze
Solar antifre
On/Off
Off
25
Water tank
Water tank
With/Without
Without
/
26
Tank sensor
Tank sensor
1/2
2
When the water tank is
unavailable, this function will be
reserved. and the LCD will display
‘Reserved’.
27
Solar heater
Solar heater
With/Without
Without
/
28
With/Without
With
Under the heating mode, if it is
set to “With”, the setting value
is defaulted to be the normal
water temperature and cannot be
adjusted; if it is set to “Without”,
the setting value can be changed
freely.
Under the cooling mode, if it is set to
“With”, the leaving water temperature
range will be 18-25 and 18 is the
default. When it is set to “Without”,
the leaving water temperature range
will be 7-25 and 7
is the default.
This setting is unavailable when the
unit is stopped.
29
Remote sensor
Remote sensor
With/Without
Without
When it is set to “Without”, the
“Control state” will be automatically
changed to “T-water out”.
30
Air removal
Air removal
On/Off
Off
/
31
Address
Address
[1~125]
[127~253]
1
/
32
Gate-Controller
Gate-Ctrl.
On/Off
Off
/