Operation Instructions for Air-to-water Heat Pump Split ECO HOME
Operation Instructions for Split Versati
11
SPLIT TYPE
(f) This mode works only for the heating/cooling function.
2.2.10 Holiday Release
when the user is out.
[Operation Instructions]
Go to the
FUNCTION
page and locate “
Holiday release
”, then, configure it through the Up/Down key
, “
On
” or “
Off
”.
[Notes]
(a) When it is activated, at the
WEEKLY TIMER
page, it is able to set some week day to “
Holiday release
”. In
this case, the “
Weekly timer
” in this day is ineffective unless it is set to “
Effective
” manually.
(b) This setting will be memorized upon power failure.
2.2.11 Disinfection
This function is intended to sanitize the water tank by raising the water temperature to 70°C under which the
[Operation Instructions]
(1) At the
FUNCTION
page, locate “
Disinfection
”, and then access to the
DISINFECTION
setting page by
pressing the OK key
.
(2) At the
DISINFECTION
setting page, select “
Set clock
”, “
Set week
” or “
Set temp
” through the Left/Right
key
and then modify the corresponding setting through the Up/Down key
.
(3)
Save
”, a pop-up window will pop up to remind if you
are determined to save this setting. If so, press the OK key
. If not, press the Cancel key
to not
save this setting.
(4) When the setting is saved, the control then will back to the
FUNCTION
page and the cursor will be where
the “
Disinfection
” is, then by the Up/Down key
, it can be set to “
On
” or “
Off
”.
Name
Name
Default
Range
Disinfection temperature
Set temp.
70°C
45°C~70°C
[Notes]
(a) It can be activated only when the “
Water tank
” is set to “
With
”.
(b) It can be set to “
On
” or “
Off
” no matter if the unit is in operation or not
(c) When “
Disinfection
” is set to “On”, if you intend to set the “
Emergen. mode
”, “
Holiday mode
”, “
Floor
Debug
”, then a window will pop up, warning “
Please disable the Disinfection Mode!
”.
(d) It can be set to “
On
” or “
Off
” no matter if the unit is in operation or not, and “
Hot water
” mode always takes