Operation Instructions for Air-to-water Heat Pump Split ECO HOME
Operation Instructions for Split Versati
24
SPLIT TYPE
User Setting
No.
Full Name
Displayed
Name
Range(°C)
Range(°F)
Default
1
Water out temperature
for cooling
WOT-Cool
7~25°C
[Without Floor]
18~25°C
[With Floor]
45~77°F
[Without Floor]
64~77°F
[With Floor]
7°C/45°F[Without Floor]
18°C/64°F[With Floor]
2
Water out temperature
for heating
WOT-Heat
25~55°C[High temp.]
25~45°C[Normal temp.]
77~131°F[High temp.]
77~113°F[Normal temp.]
45°C/113°F[High temp.]
35°C/95°F[Normal.]
3
Room temperature for
cooling
RT-Cool
18~30°C
64~86°F
24°C/75°F
4
Room temperature for
heating
RT-Heat
18~30°C
64~86°F
20°C/68°F
5
Tank temperature
T-water tank
40~80°C
104~176°F
50°C/122°F
6
Eheater-on ambient
temperature
T-Eheater
-22~18°C
-8~64°F
-7°C/19°F
7
Extra-heater-on
ambient temperature
T-Extraheater
-22~18°C
-8~64°F
-15°C/5°F
8
Max heat pump
waterout temperature
(no eheater)
T-HP Max
40~50°C
104~122°F
50°C/122°F
9
Solar kit-max water
temp
Solarwater
Max
50~80°C
122~176°F
80°C/176°F
10
Lower limit ambient
temperature at the
Weather-dependent
Mode for heating
Lower AT-
Heat
-20~5°C
-4~41°F
-15°C/5°F
Set to default value when
the Weather-dependent
Mode setting changes.
11
Upper limit
temperature at the
Weather-dependent
Mode for heating
Upper AT-
Heat
10~20°C
50~68°F
15°C/59°F
Set to default value when
the Weather-dependent
Mode setting changes.
12
Upper limit room
temperature at the
Weather-dependent
Mode for heating
Upper RT-
Heat
22~30°C
72~86°F
24°C/75°F
Set to default value when
the Weather-dependent
Mode setting changes.
13
Lower limit room
temperature at the
Weather-dependent
Mode for heating
Lower RT-
Heat
18~21°C
64~70°F
20°C/68°F
Set to default value when
the Weather-dependent
Mode setting changes.
14
Upper limit water-out
temperature at the
Weather-dependent
Mode for heating
Upper WT-
Heat
46~55°C[High temp.]
30~35°C[Normal temp.]
115~131°F[High temp.]
86~95°F
[Normal temp.]
48°C/118°F[High temp.]
35°C/95°F[Low temp.]
Set to default value when
the Weather-dependent
Mode setting changes.
15
Lower limit water-out
temperature at the
Weather-dependent
Mode for heating
Lower WT-
Heat
36~45°C[High temp.]
25~29°C[Normal temp.]
97~113°F[High temp.]
77~84°F
[Normal temp.]
40°C/104°F[High temp.]
29°C/84°F[Low temp.]
Set to default value when
the Weather-dependent
Mode setting changes.
16
Lower limit ambient
temperature at the
Weather-dependent
Mode for cooling
Lower AT-
Cool
10~25°C
50~77°F
25°C/77°F
Set to default value when
the Weather-dependent
Mode setting changes.
17
Upper limit
temperature at the
Weather-dependent
Mode for cooling
Upper AT-
Cool
26~48°C
79~118°F
40°C/104°F
Set to default value when
the Weather-dependent
Mode setting changes.
18
Upper limit room
temperature at the
Weather-dependent
Mode for cooling
Upper RT-
Cool
24~30°C
75~86°F
27°C/81°F
Set to default value when
the Weather-dependent
Mode setting changes.