5.2.3 Exhaust duct design
The machine can only overcome the air resistance at the cooling air inlet and exhaust determined
by the duct design. Any additional air resistance will reduce airflow and deteriorate machine cool‐
ing.
➤ Consult the KAESER SERVICE representative before deciding on:
■ Design of the exhaust air ducting
■ Transition between the machine and the exhaust air duct
■ Length of the ducting
■ Number of duct bends
■ Design of flaps or shutters
Use only motorised ventilation flaps and louvers on variable frequency drive (SFC) machines.
Flaps or shutters that are opened by the the action of airflow against the force of gravity do
not open sufficiently at low compressor drive motor speeds.
Further information Further information on the design of exhaust air ducts can be found in chapter 13.3.
5.3 Operating the machine in a compressed air network
If the machine is supplying an air network, the network working pressure may not exceed 16 bar
(China: 15.9 bar).
When charging a fully vented air system there is generally a very high rate of airflow through the air
treatment devices. These conditions are detrimental to correct air treatment. Air quality suffers.
To ensure the desired air quality when charging a vented air network, we recommend the installa‐
tion of an air main charging system.
➤ Consult KAESER for advice on this subject.
5
Installation and Operating Conditions
5.3
Operating the machine in a compressed air network
901848 21 E
Operating Manual Rotary screw compressor
SK
37
Summary of Contents for SK 22
Page 2: ...Original instructions KKW SSK 2 21 en SBA SCHRAUBEN SC2IO KKW SSC 2 08 20180629 105600...
Page 6: ...Contents iv Operating Manual Rotary screw compressor SK 901848 21 E...
Page 8: ...List of Illustrations vi Operating Manual Rotary screw compressor SK 901848 21 E...
Page 10: ...List of Tables viii Operating Manual Rotary screw compressor SK 901848 21 E...