KAESER SERVICE will support you in determining appropriate intervals and provide informa‐
tion on the possibilities of oil analysis.
➤ Observe national regulations regarding the use of cooling oil in oil-injected rotary screw com‐
pressors.
➤ Check operating conditions and adjust intervals as necessary; log the results in table 50 for fu‐
ture reference.
Maximum permissible oil change interval
[operating hours/years]
SIGMA FLUID
Favourable operating
conditions*
Unfavourable operat‐
ing conditions
My operating condi‐
tions
S-460
6000**/2
4000/1
S-570
6000**/2
4000/1
MOL
3000/1
2000/1
FG-460
3000/1
2000/1
FG-680
3000/1
2000/1
PANO‐
LIN HLP SYNTH 46
3000/1
2000/1
* Cool to moderate ambient temperatures, low humidity, high duty cycle
** Change intervals of >6000 perating hours are not permissible without an oil analysis.
Tab. 50 Cooling oil Change intervals
10.2.5 Regular service tasks
The table below lists necessary service tasks.
➤ Only an authorised KAESER SERVICE technician should carry out service work.
➤ Have service tasks carried out punctually taking ambient and operating conditions into ac‐
count.
Interval
Service task
Display:
SIGMA CONTROL 2
Service valves.
Compressor drive motor:
Replace the motor bearings.
up to 36000 h
Every 6 years at the lat‐
est.
Have the plastic pipes and hose lines been replaced.
up to 36000 h
Replace the control cabinet fan.
After 20 years at the lat‐
est
Replace safety-relevant components of the safety functions.
h = operating hours
Tab. 51 Regular service tasks
10 Maintenance
10.2 Following the maintenance plan
58
Operating Manual Rotary screw compressor
SK
901848 21 E
Summary of Contents for SK 22
Page 2: ...Original instructions KKW SSK 2 21 en SBA SCHRAUBEN SC2IO KKW SSC 2 08 20180629 105600...
Page 6: ...Contents iv Operating Manual Rotary screw compressor SK 901848 21 E...
Page 8: ...List of Illustrations vi Operating Manual Rotary screw compressor SK 901848 21 E...
Page 10: ...List of Tables viii Operating Manual Rotary screw compressor SK 901848 21 E...