5. Operating the boiler
When the boiler has been started and adjusted according to 4.2, operation fo the boiler is very simple.
The required temperature is set with the room thermostat, which controls the boiler. The calorifier thermostat
controls the boiler. The operation of the room thermostat is explained in the manual of the room thermostat.
If problems arise with the operation of the boiler, you will find a list of possible problems and solutions in
Appendix C.
Operating the room thermostat
Please refer to the manual thermostat
HRE Boiler
Put the boiler temperature between 75°and 80°C with the boiler thermostat.( See figure 16A, Button D)
Set the pump stop thermostat to +/- 50°C (See figure 16B)
Explanation from the number in the figure 13:
A.
Fuse holder with a glass fuse 10A 230V,
B.
On/ off switch,
C.
Analogue display for boiler temperature ,
D.
Adjust nob for boiler temperature,
E.
Reset nob maximal thermostaat.
F.
Control panel HRE boiler (backsite)
Fig. 16B
Pumpstop thermostat
Fig. 16A
< A
< B
E
< D
< C