~ 10 ~
VERTICAL FLUE GAS OUTLET
This way if installation is preferable for seagoing boats and
sailing boats, because these boats encounter large angles of
heel through waves and under sail. For this kind of flue gas
outlet, the following points are important:
Install a proper storm cowl on top of the chimney (this must
stop rain from entering) (figure 4).
Install deck fittings for installing the flue through a deck.
Install a water trap, to drain possible water caused by
condensation
Keep the chimney as vertical as possible.
Don't use more than 4 elbows 90°.
The maximum allowed length is 10 meters. At more than
10 meters in length, always contact Kabola for advice.
Every elbow of 90° is equivalent to 1 meter straight pipe.
Use outside double walled chimney pipe
With a vertical outlet always use a drain!
Hint:
To reduce the noise from flames, it is wise to install a silencer in the exhaust.
Tip:
Als maatwerk kan Kabola een dekdoorvoer onder een hoek produceren zodat de schoorsteen recht
staat.
Your Kabola supplier can provide you with all components which may be required for installation such as:
Cowls;
Flexible piping;
Single and double walled chimney pipes;
Hull and deck fittings;
Silencers;
Water traps;
Insulation.
Fig. 5
Always install a drain with tap directly on the boiler
(See Figure 5.a)
Fig. 5.a
Summary of Contents for HR Series
Page 1: ...1 Userguide HR HRE series Eng HRE CH HR CH HR Calorifier HR Combi...
Page 21: ...21...
Page 22: ...Appendix B Electrical diagram 230V HR HRE CH...
Page 23: ...Appendix B Electrical diagram 230 V...
Page 25: ...Appendix E Burnerparts...
Page 27: ...Appendix G CE declaration HR 300 HR 500 HRE 300 HRE 400 HRE 500...