~ 12 ~
HR
– CH , Calorifier and Combi boiler
Connection of the room thermostat and the function warm water on / off
For connecting the room thermostat (with the function of hot water on / off) using a 4-wire 0.75 mm²
insulated cable. The room thermostat must be connected as follows:
HR Boiler, Calorifier and combi:
Remove the right plug is located behind the dashboard (see Figure 12);
Remove the lid from the connector
Connect the wires of the room thermostat to T1 and T2 as indicated on the sticker in the plug (see
Figure 11);
HR Calorifier and combi:
Connect the wires of the hot water on / off function on the points S3 and B4 as indicated on the
sticker in the plug (frost guard) (see Figure 11);
Only at the HR boiler with calorifier are the two wires to be mounted from the boiler thermostat to
the points L1 and N. (see Figure 11);
Please remove the front of the room thermostat;
Connect the wires to the thermostat on Q14 and Q11 (see Figure 10);
Please remove the front of
the room temperature controller;
Connect the hot water on / off function on at the points Q21 and Q22 in the thermostat (see Figure
10);
If the tap is visible in the display,hot water is turned on. If not, it is disabled.
Q
21
Q
22
Q
11
Q
14
Fig. 9 Fig. 10
Fig. 12
Fig.11
Right plug