background image

32

Summary of Pushbutton Programming Commands

Name

Command

Description of Command

Authorization

Activate 
Users

300 #

NNN#

‘Activate 4. Use 4.r Acce 4.ss Code 4.’

NNN = spe 4.cific Use 4.r ID location (001 to 299)

Maste 4.r, Mgr

301 #

NNN#

‘Activate 4. Manage 4.r Acce 4.ss Code 4.’

NNN = spe 4.cific Use 4.r ID location (001 to 299)

Maste 4.r

302 #

NNN#

‘Activate 4. Se 4.rvice 4. Use 4.r Acce 4.ss Code 4.’

NNN = spe 4.cific Use 4.r ID location (001 to 299)

Maste 4.r, Mgr

303 #

‘Activate 4. M-Unit Use 4.r Code 4.’

Maste 4.r, Mgr

398 #

‘Activate 4. all Use 4.r Code 4.s’ (e 4.xce 4.pt Maste 4.r, 

Manage 4.r and M-Unit Use 4.r)

Maste 4.r, Mgr

399 #

P#

‘Activate 4. / De 4.-Activate 4. Passage 4. Mode 4.’  

(P = 0 or 1; 0 = disable 4. Passage 4. Mode 4.;  
1 = e 4.nable 4. Passage 4. Mode 4.)

Maste 4.r, Mgr

De-activate 
Users

400 #

NNN#

‘De 4.-Activate 4. Use 4.r Acce 4.ss Code 4.’

NNN = spe 4.cific Use 4.r ID location (001 to 299)

Maste 4.r, Mgr

401 #

NNN#

‘De 4.-Activate 4. Manage 4.r Acce 4.ss Code 4.’

NNN = spe 4.cific Use 4.r ID location (001 to 299)

Maste 4.r

402 #

NNN#

‘De 4.-Activate 4. Se 4.rvice 4. Use 4.r Acce 4.ss Code 4.’

NNN = spe 4.cific Use 4.r ID location (001 to 299)

Maste 4.r, Mgr

403 #

‘De 4.-Activate 4. M-Unit Use 4.r Code 4.’

Maste 4.r, Mgr

498 #

‘De 4.-Activate 4. all Use 4.r Code 4.s’ (e 4.xce 4.pt Maste 4.r, 
Manage 4.r, and M-Unit Use 4.r)

Maste 4.r, Mgr

499 #

L#

‘Activate 4. / De 4.-Activate 4. Lockout Mode 4.’ 
(Maste 4.r Use 4.r doe 4.sn’t affe 4.ct by Lockout 
Mode 4.) (L = 0 or 1; 0 = disable 4. Lockout Mode 4.;  

1 = e 4.nable 4. Lockout Mode 4.)

Maste 4.r

Diagnostic

500 #

1234567890*#

‘Manual diagnostic’

Maste 4.r, Mgr

Communication
Startup

900 # 

‘Communications startup’

Maste 4.r, Mgr

Summary of Contents for E-Plex 50 Series

Page 1: ...operations manual E Plex 50xx 30xx series...

Page 2: ...1 Passage Mode Period Procedure 6 Program the Lock for Tamper 12 Time Parameters Procedure 7 Programming the Lock for Keypad 13 Buzzer Volume Users General Information 13 User Levels 14 14 User Codes...

Page 3: ...l Feedback Message Definitions 33 User List Table 34 TABLE OF CONTENTS continued A publication of Kaba Access Data Systems Americas 2941 Indiana Avenue Winston Salem NC 27105 No part of this book may...

Page 4: ...e E Plex Lock is in the Pushbutton Programming Mode the Master Manager can enter one or more command sequences Each command sequence ends with a character that acts like an enter character At the very...

Page 5: ...per shutdown time 30 seconds Tamper attempt count 4 attempts Access code length 4 digits Latch Holdback Mode Disabled E 30xx only Swingbolt Privilege Disabled E 30xx only Privacy Privilege Disabled E...

Page 6: ...guish a program ming type command from a simple Access Code to open the door A Master or Manager User can use the same number to open the door or to put the lock in Programming Mode the only differenc...

Page 7: ...key turn counterclockwise and hold so that lock is in open position cylindrical latch is retracted Within 5 sec onds press and release the key latch 2 You have up to 5 seconds to push and release the...

Page 8: ...r Shutdown state for 30 seconds It will resume normal operations after this delay If no master code is entered during the 20 seconds delay the lock will enter a 15 minute wait period assuming the Mast...

Page 9: ...can not be changed Required User Level Master 1 To configure the E Plex Lock programmable pushbutton lock it must first be placed in Programming Mode Important This is the only programmable function...

Page 10: ...ime the software package will make the adjustment for Daylight Savings Time These must be regularly updated according to your maintenance schedule Enter 001 for date settings and 002 for time settings...

Page 11: ...Example of Complete Entry 004 10 9 Enter another to indicate the end of programming 10 You have now programmed the lock ID 1234 and for example an Unlock Time of 10 seconds for the door Procedure 5 pr...

Page 12: ...ck see visual message chart in rear section After that it will go into a Tamper Shutdown Mode and remain locked until the end of the Tamper Shutdown Time period the length of that period is configured...

Page 13: ...ing the Access Code without signs Put the lock into Pushbutton Programming Mode by entering before and after their Access Code 2 Each user Manager User Service User or Access User occupies one of the...

Page 14: ...configurable period of time This period of time starts on the first use of the code Each Service User combina tion is automatically deleted from the locks memory after its period of time expires The n...

Page 15: ...need access to the lock delete the User Code by deleting the corresponding user ID location This permits you to use the deleted user ID location for a new user If you only de activate the old code you...

Page 16: ...r with a Manager Access Code If you change the Access Code for an existing Manager the procedure is the same Required User Level Master 1 Put the lock into Pushbutton Programming Mode 2 Enter command...

Page 17: ...ccess Code of 00 you can only enter the door once If the door shuts upon exiting you will not be able to re enter This type of access is called a one shot code 7 Example of Complete Entry 102 025 2240...

Page 18: ...he lock is used with a wall bumper the warranty is null and void If a doorstop is required we recommend the use of a floor secured stop The environment and conditions of use determine the life of fini...

Page 19: ...AMERICAS 2941 INDIANA AVE WINSTON SALEM NC 27199 3770 NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES BUSINESS REPLY MAIL FIRST CLASS MAIL WINSTON SALEM NC PERMIT NO 1563 POSTAGE WILL BE PAID BY A...

Page 20: ...d to mail Name Title Company Address City State Zip Country Phone Email Name of Dealer Purchased From Date of Purchase Lock Model Number Serial Number This lock will be used in what type of facility A...

Page 21: ...21 Notes Notes...

Page 22: ...Service User Access Code is automatically deleted from the lock at the end of its specified length of time However use this procedure if you want to delete the code earlier than the specified expiry t...

Page 23: ...o Pushbutton Programming Mode 2 Enter Command 300 to activate a User Code 3 Enter the ID location NNN where NNN is the specific User ID location 023 for example 4 Example of complete entry 300 023 5 E...

Page 24: ...that are temporarily inactive Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 398 3 Example of Complete Entry 398 4 Enter another to indicate the end...

Page 25: ...1 Put the lock into Pushbutton Programming Mode 2 Enter Command 400 to de activate User Access Codes 3 Enter the code 400 NNN where NNN is the specific User ID location 023 for example 4 Example of co...

Page 26: ...ive excluding Master Manager and M Unit Codes Required User Level Master Manager 1 Put the lock into Pushbutton Programming Mode 2 Enter Command 498 to de activate all Access and Service Codes 3 Examp...

Page 27: ...the end of the code there could be a problem with the pushbutton electronics 8 Try the Diagnostic Code again 500 1234567890 to be sure you entered all the numbers correctly and in the correct order 9...

Page 28: ...e the swingbolt to unlock or lock the door Required User Level Master Manager Access user Service user 1 To Disengage retract swingbolt Enter a valid PIN to open and the lock will flash the green LED...

Page 29: ...he same as in Step 2 above Insert the mechanical key in the lock override cylinder s vertical slit and turn it clockwise to the horizontal position With the key still in this horizontal position turn...

Page 30: ...er 004 TT Unlock time setup TT 02 to 20 seconds Master Mgr 005 TT Passage Mode Timeout setup TT 01 to 24 hours duration time in hours 00 no time limit Master Mgr 006 TT Tamper time setup TT 00 to 90 s...

Page 31: ...ngth LL setting Master 102 NNN UUUU UUUU UUUU UUUU HH Add Modify Service User Access Code NNN specific User ID location 001 to 299 HH 01 to 24 hours duration time in hours 00 one time entry Combinatio...

Page 32: ...or 1 0 disable Passage Mode 1 enable Passage Mode Master Mgr De activate Users 400 NNN De Activate User Access Code NNN specific User ID location 001 to 299 Master Mgr 401 NNN De Activate Manager Acc...

Page 33: ...sec Once Invalid programming entry including duplicate access code OFF ON 1 sec Once Tamper shutdown beginning OFF ON 2 sec Once Tamper shutdown state OFF ON 1 sec 10 sec Tamper shutdown ending ON OF...

Page 34: ...me User Type 001 002 003 004 005 006 007 008 009 010 011 012 013 299 Optional Easy To Use software called E Plex Standard is also available for this product to program and maintain doors and users For...

Page 35: ...35 Notes Notes...

Page 36: ...C2 Kaba Access Data Systems Americas 2941 Indiana Avenue Winston Salem NC 27105 USA Tel 800 849 8324 336 725 1331 Fax 800 346 9640 336 725 3269 www kaba adsamericas com PKG3219 0314...