LOCK RESPONSES 
Standard Operations 
Entry Devices with LEDs (3125, 3190 and 3750-K) respond with both LED flashes and beeps. 
•  Single signal - one (1) LED flash and one (1) beep indicate the operation is complete. 
•  Double signal - two (2) LED flashes and two (2) beeps indicate entry is valid or accepted. 
•  Triple signal - three (3) LED flashes and three (3) beeps indicate invalid or not accepted. 

NOTE: The 8130 Entry Device (no LED) responds with beeps only. 

Additional Operations 
•  Delay Period – The LED will flash once every second.
•  Open Period – The LED will flash twice a second, and the Entry Device will beep every 
  10 seconds.
•  If any key is pressed, the Lock will flash the LED and beep three times.
•  Penalty Period - The LED will flash every ten (10) seconds. 
•  Low Battery Warning - During a Lock opening, the LED will flash and Entry Device will 
  beep repeatedly. 

SUPER MASTER RESET

SMR will reset the lock back to factory state, but the SM code remains unchanged. The default 
code of 5-5-5-5-5-5-5-5 must be changed before the Manager default code is changed or the Super 
Master Reset function will be permanently lost.

PROCESS IS AS FOLLOWS:
•  Action - Press and hold [0] key for 3 seconds
•  Result – Lock beeps twice and the LED remains ON throughout the entire process.
•  Action – Enter default code of 5-5-5-5-5-5-5-5. Press and hold last digit until the unit gives a 
  double beep.
•  Result – Command Menu access is granted.

SMR HAS ONLY 2 COMMAND OPTIONS AVAILABLE:
•  If press [0] = Change Code, (1 time use)
•  Enter current default Super Master code of 5-5-5-5-5-5-5-5
•  Enter new Super Master code (ex. 8-8-8-8-8-8-8-8) then double beep.
•  Enter new Super Master code again to confirm (ex. 8-8-8-8-8-8-8-8) then double beep the SMR 
  code is set.
NOTE: Once the default code is changed to a new code the code can never be changed. A reset box 
must be used to reset.

•  If press [8] = Reset the Lock
•  Lock will signal a long beep to indicate it was reset
I• f any other key is pressed then the lock beeps 3 times and the operation is ended.

PROGRAM THE LOCK

EXIT FACTORY STATE 
CAUTION: 
Always perform this operation with the door open! 

1. Press and hold the 0 key until lock double signals. 
2. Enter the default Manager combination, 5-5-5-5-5-5. 
The lock will open. Lock is now in Manual Setup. 

SET COMBINATION LENGTH 
1. Enter the default Manager combination (5-5-5-5-5-5) and 

hold down last digit of combination 

  until lock double signals twice release and the LED stays on
2. 

PRESS 8

Summary of Contents for LA GARD COMBOGARDPRO 39E

Page 1: ...from 5 5 5 5 5 5 Once the combination is changed NO ADDITIONAL USERS can be added PROGRAMMABLE LOCK FEATURES MODES Multiple Modes may be selected Silent Alarm Alarm Box Required If enabled this option...

Page 2: ...low and should be replaced immediately If the battery level becomes too low to safely operate the Lock pressing any key will initiate the low battery warning The battery must be replaced before the Lo...

Page 3: ...ill be permanently lost PROCESS IS AS FOLLOWS Action Press and hold 0 key for 3 seconds Result Lock beeps twice and the LED remains ON throughout the entire process Action Enter default code of 5 5 5...

Page 4: ...esired Lock Mode configuration to confirm NOTE Dual Mode cannot be selected if at least one additional User has not been enrolled User 9 must be enrolled to use the Time Delay Override function MODE T...

Page 5: ...m 5 The lock is now active and the configuration is frozen 6 Test lock operation several times before closing the door NOTE If default combinations are used it is recommended that they be changed New...

Page 6: ...P N 735 028 Rev M 11 14 copyright 2006 2014 Kaba Mas LLC Page 6 of 8 NOTES...

Page 7: ...P N 735 028 Rev M 11 14 copyright 2006 2014 Kaba Mas LLC Page 7 of 8 NOTES...

Page 8: ...Mas shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 20...

Reviews: