background image

(P/N) 735.028 Rev M • 11/14 

© copyright 2006-2014 

Kaba Mas LLC

Page 2 of 8

TIME DELAY 
•  Delay Period 1 - 99 minutes 
•  Open Period 1 - 19 minutes 
COMBINATION LENGTH 
A combination length from six (6) to nine (9) digits may be selected. 
NOTE: To maintain the VdS Class 2 and EN 1300 Class B certification when the duress alarm feature 
is used, a combination length of 7 digits or longer must be selected. 

LOCK USERS 
Manager 
•  Open Lock 
•  Change Combination 
•  Enable/Disable Users 
•  Delete Users 
•  Set Time Delay Values 
•  Audit Lock 

Up to 9 Users 
•  Open Lock 
•  Change Combination 

STANDARD LOCK FEATURES 
Wrong Try Penalty 
•  Entry of four (4) consecutive invalid combinations initiates a five (5) minute delay penalty. 
  Lock responses during the penalty period are as follows: 
    - The LED will flash every ten (10) seconds. 
    - If any key is pressed, the Lock will flash the LED and beep three times. 
•  Once the penalty period has ended, two (2) consecutive invalid combinations will initiate another 
  five (5) minute penalty period. 
Low Battery Warning 
•  Repeated audio/visual signals (LED flashes/beeps) during Lock opening indicate the battery is low
  and should be replaced immediately. 
•  If the battery level becomes too low to safely operate the Lock, pressing any key will initiate the 
  low battery warning. The battery must be replaced before the Lock will operate. 
Audit Records 
•  Lock records the last 63 events in non-volatile memory. 
•  Audit file cannot be deleted from the Lock. 
•  Only the Manager can audit the Lock. 
•  ComboGard Pro auditing software and an Interface Adapter are required to retrieve a Lock audit. 

LOCK OPERATING CONVENTIONS 
•  If a mistake is made while entering keystrokes, wait thirty (30) seconds and repeat operation. 
•  To access lock commands, enter combination and hold down the last digit until Lock double 
  signals and the LED stays on. 
•  In Dual Mode, two combinations are required to operate the Lock. 

NOTE: In Dual Mode, a valid User combination must be entered first, followed by the Manager 
combination to access the following Manager Commands: 1, 2, 3, 7 and 9. 

•  Lock must be opened within 4 seconds once a valid combination has been entered. 
•  To open a container with a Swing Bolt Lock, turn the container handle to the open position and 
  open the door. 
•  To open a container with a Dead or Spring Bolt Lock, turn the keypad or dial to retract the bolt 
  and open the door. 
•  When closing a container, verify that it has been secured. 

Summary of Contents for LA GARD COMBOGARDPRO 39E

Page 1: ...from 5 5 5 5 5 5 Once the combination is changed NO ADDITIONAL USERS can be added PROGRAMMABLE LOCK FEATURES MODES Multiple Modes may be selected Silent Alarm Alarm Box Required If enabled this option...

Page 2: ...low and should be replaced immediately If the battery level becomes too low to safely operate the Lock pressing any key will initiate the low battery warning The battery must be replaced before the Lo...

Page 3: ...ill be permanently lost PROCESS IS AS FOLLOWS Action Press and hold 0 key for 3 seconds Result Lock beeps twice and the LED remains ON throughout the entire process Action Enter default code of 5 5 5...

Page 4: ...esired Lock Mode configuration to confirm NOTE Dual Mode cannot be selected if at least one additional User has not been enrolled User 9 must be enrolled to use the Time Delay Override function MODE T...

Page 5: ...m 5 The lock is now active and the configuration is frozen 6 Test lock operation several times before closing the door NOTE If default combinations are used it is recommended that they be changed New...

Page 6: ...P N 735 028 Rev M 11 14 copyright 2006 2014 Kaba Mas LLC Page 6 of 8 NOTES...

Page 7: ...P N 735 028 Rev M 11 14 copyright 2006 2014 Kaba Mas LLC Page 7 of 8 NOTES...

Page 8: ...Mas shall not be liable for technical or editorial errors or omissions contained herein nor for incidental or consequential damages resulting from the furnishing performance or use of this material 20...

Reviews: