(P/N) 735.028 Rev M • 11/14
© copyright 2006-2014
Kaba Mas LLC
Page 4 of 8
3. Enter combination length (6, 7, 8, or 9).
4. Press
0.
5. Enter combination length a second time and press
0 to confirm.
Example setting a combination length to seven digits:
Enter 5-5-5-5-5-5 (hold down the last number) 8 - 7-0-7-0.
6. To test, enter default Manager combination 5-5-5-5-5-5-5 (all fives to length of combination). Lock
will signal twice and lock will open.
NOTE: If combination length is changed after Users are enrolled, all Users will be deleted and
must be re-enrolled.
CAUTION: To maintain the VdS Class 2 and EN 1300 Class B certification when the Silent alarm
feature is used, a combination length of 7 digits or longer must be selected.
CONFIGURE LOCK MODES
1. Enter default Manager combination (all fives to length of combination) and
hold down last digit of
combination until lock double signals twice release and the LED stays on.
2.
PRESS 8.
3. Enter
0 (this maintains current combination length value).
4. Enter desired Lock Mode configuration from the chart below.
5. Enter
0 and re-enter the desired Lock Mode configuration to confirm.
NOTE: Dual Mode cannot be selected if at least one additional User has not been enrolled. User 9
must be enrolled to use the Time Delay Override function.
MODE
TIME DELAY OVERRIDE
DUAL MODE
DURESS ALARM
0
1
P
2
P
3
P
P
4
P
5
P
P
6
P
P
7
P
P
P
ACTIVATE USERS
1. Enter Default Manager combination (all
5’s to length of combination) and hold down last digit of
combination until lock double signals twice release and the LED stays on.
2.
PRESS 1.
3. Enter User number (1 - 9.)
4. Enter the NEW User combination
5. Re-enter the User combination to confirm.
6. Repeat steps 1- 5 for each User to be added.
NOTE: If a User is not enrolled during setup, the User is blocked and cannot be added later. New
combinations are rejected when less than 2 digits are different from existing combinations.
Set Time Delay Values:
The Delay and Open Periods may be set up at this time or later by the Manager. To set the Time
Delay Periods follow the instructions below or refer to Manager Instructions 732.018.
1. Enter Manager combination and
hold down last digit of combination until lock double signals
release and the LED stays on.
2.
PRESS 9.
3. Enter two-digit Delay Period value (00 to 99 minutes) followed by the two-digit Open Period value
(00 to 19 minutes).