5
Appendix
5.8 LWF ASR Map
Page 110
Docu-No.: 0590020601-EN Rev. 1.6.0
45 DRIVE CMD
CEILING
• Drive command has reached the
limit <DC CEILING>
46 DRIVE CMD
HIGH
• The drive command has exceed the
value <DRV CMD HI> Limit in the
<ALARM> menu.
47 DRIVE CMD
LOW
• The drive command has dropped
below the value <DRV CMD LO>
Limit in the <ALARM> menu.
48
CHECK_MOTOR_B
RUSHES
• DC motor brushes may be wearing
out and ready to fail.
49
RESET_WHILE_RU
N
• It is set if the feeder was running
before the power down or reset
occurred
50 ACF_FAIL
• Actiflow has an alarm
52 FEEDFACT. BAD
• Feedfactor is zero or feeding
condition changed so that the
feedfactor exceed the set limit in the
<ALARM> menu <FF DEV LIMIT>.
53
SCALE
OVERRANGE
• The weight on the scale is above the
scale gross range permitted.
54
SCALE
UNDERRANGE
• The weight on the scale is below the
zero or gross weight < 0.
ASR(
Alarm number)
Description
Table page 5 of 6