3
Other Programming
3.1 Setting refill parameters
Page 66
Docu-No.: 0590020601-EN Rev. 1.6.0
3.1.4
Setting the Refill Timer
Refill timer set-up equipment required:
• Stop watch
Refill timer set-up procedure:
1. Execute a refill
2. Start a stop watch when the refill begins
3. Stop the stop watch when the refill is compete and the discharge
device stops discharging product.
4. Select the ALARM menu.
5. Select the sub-menu ALARM LIMITS.
6. Select <MAX REFILL TIME> parameter.
7. Enter a value =1.25* the stop watch value.