Instruction Manual
Section Five
(B985JG) if the cutter has no corner radii, or install the optional 'V Gauge
(B985J) if it already has corner radii. The Crossfeed of the machine should be
out far enough from the wheel so that the Gauge stands in front of the cup
wheel or straight wheel.
C. Mount the cutter with peripheral
cutting edges facing up as shown in
Photo 46, or down if space permits a
toothrest set-up from below. Mount
the Swinging Arm (I) and lower
swivel (H) on the fixture Upper Slide
so that the cutter teeth, when
mounted on the
¼
inch Stud (J), will
be just short of the Pivot Axis. Lock
the swivels and' tighten the cutter on
the Stud with the appropriate size of
Friction Collar and Washer (B923EF)
and Nut (B923EN) so that it can just
be rotated about the Stud.
D. Mount the Universal Toothrest (BA940), shown in Photo 46, if cutter edge
faces up at the point of grinding. Use the B620G Swivel Stud as shown. Use
the spring-loaded micrometer so that the cutter can be rotated to bring a new
tooth on centerline with the cutter center by placing the BA939 Height Gauge
on the Upper Slide as shown in Photo 43.
On tilthead grinders, the clearance for both the periphery and side may be
taken directly by tilting the Wheelhead if the clearance is to be common. If
more clearance is needed on the periphery than on the side teeth, create
slide clearance by tilting the fixture Saddle (50) the desired amount for side
teeth
(FIXTURE IS CALIBRATED IN 5 DECREE INCREMENTS),
but add an
PHOTO 46
— 5 7 -
A
B
C
D
Max
1
¼