VR-N100U
USERS
MANUAL
Page 82 of 98
All Items Are Subject To Change Without Notice
Feb. 2004 Rev 1.0
6.2.6. CN22: Software Reset
Pin
Signal
1 Reset
2 GND
The software reset is a means to manually reset the appliance temporarily back to manufacturer’s default settings.
NOTE: VR-N100U rackmount systems do not utilize the manual software reset option.
6.3. BIOS
The settings for the customized Phoenix-Award BIOS for the industrial server board have been optimized for the VR-N100U
security application. No changes to the CMOS are required.
6.4.
Adaptec SCSI BIOS
The onboard Adaptec SCSI BIOS settings for the server board have been for the VR-N100U security application. No changes
to the Adaptec SCSI BIOS are required. The default settings are:
Adaptec Settings
Defaults
SCSI Controller ID
7
SCSI Controller Parity
Enabled
SCSI Controller Termination
Enabled
Sync Transfer Rate (SCSI ID #0~15)
160 MB/Sec
Initiate Wide Negotiation
Yes
Enable Disconnection
Yes
Send Start Unit Command
Yes
BIOS Multiple LUN Support
No
Include in BIOS Scan
Yes
Reset SCSI Bus at IC Initialization
Enable
Display <Ctrl><A> Message During BIOS Initialization
Enable
Extended Init 13 Translation for DOS Drives > 1 GByte
Enable
POST Display Mode
Verbose
SCSI Controller Int 13 Support
Enabled
Domain Validation
Enabled
Support Removable Disks Under Int 13 as Fixed
Disabled