32
7. Registering connection points
Start the VN-C30U controller (vn-c30u.exe). Select
New
from the
File
item in the menu and then specify the connection point.
The folder "VN-C30U Name" will be
created automatically in the folder
specified here. Recorded files will be
saved here. (Refer to page 50 concerning
recording.)
"
Start recording on connection
"
determines whether or not recording
will star t automatically upon the
connection of VN-C30U.
Enter the IP address and name of the
VN-C30U connection point.
(
192.168.0.2
is used as an example
in the diagram.)
When using a network backbone that does not offer sufficient capacity to
enable reception of the MPEG images, the images received within the
buffering period are displayed together after the buffering period has
expired. If set to 4 seconds, for example, nothing will be displayed for 4
seconds after the connection is established, and after 4 seconds the
images that have been received up to then are displayed. Then there will
be another 4 seconds of buffering before images are displayed again.
This setting is ignored if the network backbone capacity is larger than the
bit rate of the MPEG images being received. The factory default setting is
1 second.(90 sec is the maximum value that can be set.)
Set the Network time-out (seconds). Set
a long Network time-out in case the
image does not display correctly when
connecting to the network.
See the next page.