15
2. Connecting to the network
Turn on the power of only one VN-C30U unit.
When network connection is completed and the power is turned on, the
VN-C30U unit will be connected to the network at the following IP address.
Factory Default IP address 192. 168. 0. 2
•
About the power supply connection cable
• Length: 30m(98 feet) or less.
• Recommended model: UL1007, UL1015 or equivalent cable with wire
equivalent to ID AWG #20 or larger.
Caution
When shipped from the factory, the IP address of all VN-C30U units is set
to 192.168.0.2 Consequently, if multiple units are installed in the same
LAN environment and the power is turned ON at the same time, duplication
of IP addresses will occur and correct access will not be possible. Always
turn the power on for only one unit at a time. Once duplication of IP
addresses has occurred (and after confirming that only one VN-C30U
exists in the same LAN environment), wait a while (10 minutes or longer),
or turn off the power of all the network devices on the same LAN
environment, before turning the power ON again. If this is not done, it may
not be possible to access the VN-C30U.
100BASE-TX
10BASE-T/
DC12V
10 BASE-T, CAT-5 cable
12VDC
power supply
❉
Use a straight cable when
connecting to a hub.
Use a cross cable when
connecting directly to a PC.
Power supply connection cable
Caution
VN-C30U unit is intended to be supplied by a Listed Direct Plag-In Power
Unit marked “Class 2” and rated from 11 to 15 V dc, 2 to 2.5 A.