SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
72 JVC PROFESSIONAL, IMAGING PRODUCTS
q
All front panel keys
q
Alarm history read
q
Alarm Input Status read
RS-232 baud rates are selectable from 1200 to 9600. The factory default is 9600. To set the baud
rate, select the RS-232 section of the COMMUNICATIONS sub-menu. Refer to the
SW-D8000U's
RS-232 Remote Control Protocol
data sheets in the rear of this manual for more details.
The figure shows the socket on the multiplexer as seen from the back of the unit. The numbers are
marked on the connector itself, although they may difficult to read.
PIN NUMBERS
FUNCTION
Pin 2
Receive Data (RX)
Pin 3
Transmit Data (TX)
Pin 5
Ground (GRD)
RS485
The
SW-D8000U
can have up to 15 optional remote keyboards controlling it through the RS-485
network. In addition, a single remote keyboard can control up to 15 different
SW-D8000U
units, (or
a mixture of keyboards and multiplexers totaling 16 devices), installed in a multi-drop configuration.
The
SW-D8000U
unit address on the RS-485 network is programmable in the RS-485 section of the
COMMUNICATIONS submenu. You need set the address of the multiplexer on the network 1-15.
Using RS-485 correctly wired, the total length of all connections on one configuration of multiple
units and multiple keyboards can be up to 3,200 feet (1,000 meters) from end to end. A remote
keyboard can thus be up to 1,000 meters from the actual unit without the need for additional
transmission equipment.
RJ45 Socket Looking from the rear of the multiplexer
The connection details are the following:
Pin
Use
1
GND
1
5
9
6
1 2 3 4 5 6 7 8