SW-D8000U, 16CH. COLOR VIDEO MULTIPLEXER
26 JVC PROFESSIONAL, IMAGING PRODUCTS
will activate automatically through this manual activation. The programmed parameters for the
alarm, such as latching mode, buzzer setting and relays will determine the alarm actions.
In addition, the camera associated with the alarm will be recorded as programmed.
To deactivate this function, simply reset the alarm as normal by pressing the ALARM key.
3.4.2
ALARM DISPLAYS IN LIVE MODE
During alarms in Live mode, Monitor-A will automatically switch to a full-screen view of the
cameras in alarm. Monitor-B is simultaneously switched full-screen to the camera in alarm.
NOTE:
The alarm screen on Monitor-A will be displayed only while an alarm is active.
Once an alarm times out or is cleared, the display will automatically revert to the
screen displayed before the alarm. It is hence very important that the installer
selects the best alarm-latching mode for alarm displays.
If the operator changes the screen format while an alarm is active, then the unit will continue to
display the operator’s selection after the alarm clears - it will not revert to the pre-alarm screen
display.
Monitors A and B Full-Screen during alarms:
During alarms in Live mode, Monitors A and B will automatically switch to a full-screen display
of the camera in alarm. If multiple alarms are active, Monitors A and B will automatically
sequence between the alarm cameras at a fixed 1-second dwell. This dwell is not
programmable. Monitor-B cannot freeze images.
NOTE:
The Monitor-B screen will not revert to its original fixed display after the alarm is
cleared. It will continue to display the last alarm camera. However if sequencing
was active on Monitor-B before the alarm, then Monitor-B will continue to sequence
after the alarm is cleared.
3.4.3
ALARM DISPLAYS IN PLAY MODE
Monitor-A during Play mode - Recorded Alarms:
In the Play mode the Monitor-A display will not automatically provide custom alarm displays
based on recorded alarm status. Monitor-A will display the Playback images from the VCR
according to operator selected formats, and will display the normal “
A
” alarm indicator only if a
camera was in alarm at the time that a recording was made.
CAUTION:
If a camera that had an alarm at the time of recording is not selected by the
operator for display, there will be
no on-screen indication at all that the alarm
occurred. Thus if an operator is looking for cameras in alarm during Playback,
ensure that all cameras on tape are displayed by using a 16-channel multi-
screen.
Monitor-B during Play mode:
Monitor-B will continue to display Live images, according to the operator’s selection. If a Live
alarm occurs during Play mode, Monitor-B will automatically switch to the camera in alarm. It
will sequence at a 1 second dwell time for multiple cameras in alarm. After the operator has
canceled the alarm, Monitor-B will continue to display the alarm camera that was on the screen
at the time that the alarm was canceled, or will continue to sequence if sequencing was
enabled.
Alarm LED and Internal buzzer in PLAY Mode: