3-6
Signal
(A)
•
RF signal
(Audio: L-ch 5 kHz 14% modulated)
Mode
(B)
•
Tuner
•
EE
Equipment
(C)
•
Audio level meter
Measuring point
(D)
•
IC1501 pin 26
EVR mode
(F1)
•
Jig code “57”
EVR address
(F2)
•
A : 24
(F3)
•
Jig code “22” and “24”
(F4)
•
Jig code “18” or “19” (C/-)
Specified value
(G)
•
Minimum level
Adjustment tool
(H)
•
Jig RCU [PTU94023B]
(1) Set an audio signal mode of the RF signal generator to
alternate L-ch 5 kHz 14% modulated.
(2) Connect the equipment (C) to the measuring point (D).
(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by transmitting the code (F3)
from the Jig RCU.
(5) Transmit the code (F4) from the Jig RCU to adjust so that
the level of the measuring point(D) becomes the speci-
fied value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
3.5.5
Separation - 2
Signal
(A)
•
No. signal
Mode
(B)
•
Tuner
•
EE
Equipment
(C)
•
Frequency counter
Measuring point
(D1)
•
IC1501 pin 26
Short point
(D2)
•
C1505 (–) terminal
EVR mode
(F1)
•
Jig code “57”
EVR address
(F2)
•
A : 25
(F3)
•
Jig code “22” and “25”
(F4)
•
Jig code “18” or “19” (C/-)
Specified value
(G)
•
78.67 ± 0.5 kHz
Adjustment tool
(H)
•
Jig RCU [PTU94023B]
(1) Connect the short wire between the short point (D2) and
the GND (Ground).
(2) Connect the equipment (C) to the measuring point (D1).
(3) Set the VCR to the EVR mode by transmitting the code
(F1) from the Jig RCU.
(4) Set the EVR address to (F2) by transmitting the code (F3)
from the Jig RCU.
(5) Transmit the code (F4) from the Jig RCU to adjust so that
the frequency of the measuring point (D1) becomes the
specified value (G).
(6) Release the EVR mode of the VCR by transmitting the
code (F1) from the Jig RCU again. (When the EVR mode
is released, the adjusted data is memorized.)
(7) Disconnect the short wire between the short point (D2)
and the GND (Ground).
3.5.6
SAP VCO