E-24
4. CONNECTIONS
REAR P
ANEL CONNECT
ORS (Continued)
DA
T
A
I/O
ALARM INPUTS 1 to 16
TTL
level (Make/Break), input duration 70 ms or more.
REF
.
:
“CONTROL
UNIT
SCREEN” on page 28 and
“POLARITY
item of DA
T
A
I/O SCREEN (INPUT
ASSIGNMENT
SCREEN)” on page 31 for the Make/
Break switching.
ALARM/SELECT OUTPUTS 1 to 16
Alarm or selection output.
Open-collector output of a LOW pulse for between 500 ms
and 1000 ms.
Max. voltage 30 V
, current 30 mA.
UNIT ALARM
Open-collector
, LOW output during the alarm time period.
Maximum voltage, 30 V
, current 30 mA.
CAM SW
●
Connect to the CAM SW OUT
(camera switching signal
output) terminal of the time-lapse VCR.
T
ime-lapse re-
cording is not available if this connection is not made.
●
Set “polarity” according to the VCR to be used. When
using a JVC time-lapse VCR, set to “LOW”.
REF
.:
“CONTROL
UNIT
SCREEN” on page 28 and “CAM
SWITCH item of DA
TA
I/O SCREEN” on page 30.
REF
. : “DA
T
A
I/O SCREEN” on page 30 for the input/output signal switching.
DATA I / O
COM
1
2
3
4
5
6
7
8
COM
9/1
10/2
11/3
12/4
13/5
14/6
15/7
16/8
COM
COM
COM
CAMERACAMERA
SW
UNITUNIT ALARM
AUTO
HOLD
Install a ferrite core on cables connected to the DA
TA
I/O ter-
minals and to the
TO
CAMERA
terminals as shown in the dia-
gram on the left. Keep the ferrite core as close as possible to
the remote control unit.
Installing the Ferrite Core (A
CCESSOR
Y)
E-25
5. MENU SCREEN SETUPS
FLO
W OF MENUS
POSITION SETUP
SET UP screen
CAMERA
CONTR
OL UNIT screen ( REF
. :
P
age 28)
POSITION SETUP screen ( REF
. :
P
age 27)
CAMERA screen ( REF
. :
P
age 28)
OPTION screen ( REF
. :
P
age 29)
MAX CAMERA (Displa
y
ed at B Mode only)
P/T SPEED
SERIAL-2 (Displa
y
ed at B Mode only)
CAMERA SELECTION (Displa
y
ed at A Mode only)
CAMERA SELECTION screen ( REF
. :
P
age 29)
FA
CT
OR
Y SETTING
D
ATA
I/O screen ( REF
. :
P
age 30)
CAM SWITCH (Displa
y
ed at A Mode only)
INPUT ASSIGNMENT
INPUT ASSIGNMENT screen ( REF
. :
P
age 31)
I/O
ALARM screen ( REF
. :
P
age 32)
AU
TO
SEQ
UENCE screen ( REF
. :
P
age 32)
(Displa
y
ed at A Mode only)
PRIORITY
ALARM TIME
B
UZZER TIME
TERMINAL
CAMERA
POSITION
ALARM TEXT
POLARITY
FA
CT
OR
Y SETTING screen ( REF
. :
P
age 29)
For details of each screen, please refer to the reference pages 26 to 28.