Troubleshooting
No iris feedback on LED Bar for RM-LP250M
If the RM-LP250M do not have iris feedback on the LED Bar it could be an Iris Range issue. If the Serial
Monitor during the bootup would displays :
“Successfully recalled Limit
0
and lowr: 0 At location: 0”
And not the number 255 iris in the LED Bar will not be shown.
The iris range limitation is used to set a range for the joystick on the RM-LP250S.
In order to resolve this the action “Iris Range - Reset point” must be triggered for the impacted Device
Cores.
20