No. 51957
GM-P421U
GM-P420UG
39
■
■
■
■
ADJUSTMENT
Item
Test equipment
Test points
Ad justment
locations
Ad justment procedure
*
Make sure that NO SYNC is displayed when the power is
turned ON.
*
Carry out aging for more than 5 minutes.
POWER
(Vd / Vs)
voltage
adjustment
Digital
voltmeter
CNT P connector
1pin : Vd
2pin : GND
3pin : NC
4pin : Vs
VR551
VR351
1. Adjust the VR551 so that the voltage of the CNT P pin 4
becomes the panel Vs s etting value. However, the following
adjustment should be carried out in acc ordance with the
designated Vs value of the panel. (The adjusted values should
fall within the shaded area in the figure.)
*
When the designated Vs value of the panel is less than 172V :
Designated Vs value of the panel +/- 1.0V
*
When the designated Vs value of the panel is more than 172V :
Uniformly 172V +/- 1.0V
2. Adjust the VR351 so that the voltage of the CNT P pin 1
becomes the panel Vd setting value (s pec ified value of the
panel : around 60V) +/- 1.0V.
NOTE
: The designated voltage value(Vd/Vs) of the PDP is written
on the little label posted on the bac k of the PDP.
VCO
adjustment
Color bar
signal
generator
(NT SC)
1. Input the NTSC color bar s ignal to the VIDEO A terminal.
2. Enter the SERVICE MENU and select the VCO ADJUST.
3. Press the “ ” and select YES, then the adjustment is carried
out automatically with the micro computer.
4. Make sure that “ADJUSTMENT OK” is displayed.
5. After turning the power off, wait a few seconds, then turn the
power on again and mak e sure that the color bar is normal.
(adjustment voltage)
( V )
173
172
171
170
174 ( V )
173
172
171
Designated Vs
voltage of t he panel.
•
Array of CNT P (voltage TP connector)
1. Vd : Value written on the panel. It is set to about 60V.
2. GND : (
$
)
3. NC. :
――
4. Vs :Value written on the panel. It is s et to about 170V.
Voltage (Vd/Vs)
indic ated rabel